logo
خانه محصولات

ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument

گواهی
چین DONGGUAN LONROY EQUIPMENT CO LTD گواهینامه ها
چین DONGGUAN LONROY EQUIPMENT CO LTD گواهینامه ها
چت IM آنلاین در حال حاضر

ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument

ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument
ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument

تصویر بزرگ :  ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument

جزئیات محصول:
محل منبع: گوانگدونگ ، چین
نام تجاری: lonroy
پرداخت:
مقدار حداقل تعداد سفارش: 1

ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument

شرح
محدوده هدایت حرارتی: 0.001 ~ 100w/mk زمان اندازه گیری: 1-60 ثانیه
دقت: بهتر از 3 درصد دامنه دما: دمای اتاق اندازه گیری استاندارد ، اختیاری -20 درجه سانتیگراد 120 درجه سانتیگراد
اندازه نمونه: > ارتفاع 10 میلی متر ،> قطر 45 میلی متر منبع تغذیه: AC 220 ولت ± 10 ٪ ؛ 50/60 هرتز
قدرت ماشین: <500 وات ولتاژ: 220 ولت
طبقه حفاظت: IP57 روش اندازه گیری: منبع گرمای هواپیمای گذرا (TPS)
نوع کاوشگر: دیسک داغ استاندارد مرجع: ISO 22007-2: 2008 ، GB/T32064-2015
الزام نمونه: سطح نسبتاً مسطح تست اتوماسیون: کنترل شده توسط کامپیوتر
مصرف برق: 1 کیلو وات
برجسته کردن:

ISO 22007 thermal conductivity meter,rapid thermal conductivity tester,DRE-2C thermal analyzer

,

rapid thermal conductivity tester

,

DRE-2C thermal analyzer

ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument
Product Description

The ISO 22007 DRE-2C Rapid Thermal Conductivity Meter is a precision instrument designed for accurate thermal conductivity measurements using the transient plane heat source method (TPS). This advanced technology provides fast, reliable results across a wide range of materials.

Key Features
  • Utilizes transient plane heat source method (TPS) for rapid measurements
  • Direct heat propagation measurement saves significant time
  • Unaffected by contact thermal resistance issues common in static methods
  • Minimal sample preparation required - only a relatively flat surface needed for solids
  • Wide measurement range suitable for various material types
  • Automated computer-controlled operation for consistent results
  • Compliant with ISO 22007-2:2008 and GB/T32064-2015 standards
Technical Specifications
Parameter Specification
Thermal conductivity measurement range 0.001 - 100 W/m·K
Measurement time 1-60 seconds
Accuracy Better than 3%
Temperature range Standard room temperature (optional ranges available)
Sample size requirements Minimum 10mm height, 45mm diameter flat surface
Power requirements AC 220V±10%; 50/60 Hz, <500W
Measurement Advantages
  • Fast measurement speed (1-60 seconds per test)
  • Minimizes natural convection effects during testing
  • Versatile application across insulation and high thermal conductivity materials
  • Special sample cylinder included for rock and soil measurements
  • Simple operation with automated computer processing
ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument 0
ISO 22007 DRE-2C Rapid Thermal Conductivity Meter
ISO 22007 DRE-2C Rapid Thermal Conductivity Meter Thermal Conductivity Testing Instrument 1
Product Certification and Company Information

اطلاعات تماس
DONGGUAN LONROY EQUIPMENT CO LTD

تماس با شخص: Kaitlyn Wang

تلفن: 19376687282

فکس: 86-769-83078748

ارسال درخواست خود را به طور مستقیم به ما (0 / 3000)