logo
ホーム 製品実験室検査機

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

認証
中国 DONGGUAN LONROY EQUIPMENT CO LTD 認証
中国 DONGGUAN LONROY EQUIPMENT CO LTD 認証
オンラインです

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

大画像 :  Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

商品の詳細:
起源の場所: 中国
ブランド名: Lonroy
証明: ISO ASTM CE
お支払配送条件:
最小注文数量: 1
価格: Negotaible
パッケージの詳細: 木製パッケージ
受渡し時間: 5-8勤務日
支払条件: L/C、D/A、D/P、T/T、Western Union
供給の能力: 200

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

説明
電圧: 220 V、380 V 保護クラス: IP56
時間決断: 1秒 タイミングの正確性: ±10秒 / 24時間
ステージ範囲: 1-200ステージ サイクル数: 最大65535
作業モード: 一定電流排出、一定の排出、一定抵抗排出、多段階の排出、多段階環状放電、停止、一時停止 ステージ時間: 1秒-1000時間
記録間隔: 1秒-1000時間 ネスティングサイクル: 最大6層
放電電圧: *v〜*v 総電流範囲: 0a〜*a
現在の精度: ±0.5%fs 現在の決断: 0.01A
電圧正確さ: ±0.5%fs
ハイライト:

IP56 Protection Battery Discharge Testing Machine

,

220V Voltage Single Cell Recovery Discharge Equipment

,

380V Voltage Recycling Discharge Device

Battery Recovery Discharge Testing Machine Single Cell Recovery Discharge Equipment Recycling Discharge Device
This advanced battery recovery discharge testing machine is designed for efficient discharge processes during lithium-ion battery recycling operations. The equipment features customizable configurations and intelligent discharge management for optimal performance.
Specifications and Components
  • Each unit consists of customizable main channels (quantity adjustable per requirements)
  • Complete set includes discharge main channels, battery racks, connection lines, and clamps
  • Versatile crocodile clip battery clamps compatible with both cylindrical and pouch batteries
Equipment Features and Capabilities
Application Scope
Primarily designed for discharge processes in single lithium-ion battery recycling operations.
Key Functions
  • Parallel Discharge: Each main channel supports simultaneous connection of 20 batteries with independent operation
  • Safety Protection: Optimized circuit design prevents short circuits, reverse connections, and uncontrolled discharge
  • Intelligent Equalization: Automatic adjustment of discharge current based on battery voltage (up to 20A)
  • Voltage Monitoring: Real-time collection and comparison of battery voltages with dynamic display of highest/lowest values
  • PC Integration: Full equipment control via upper computer software with detailed voltage monitoring
  • Safety Checks: Automatic battery presence detection (0.5V threshold) with alarm system for contact faults
  • Data Recording: Automatic generation of termination data when batteries reach set voltage thresholds
Technical Specifications
Parameter Specification
Main channels per cabinet Customizable quantity
Auxiliary channels per main channel 20 units
Energy consumption Discharge energy converted to heat via electronic load
Working modes Constant current, constant power, constant resistance, multi-stage, cyclic discharge
Stage termination conditions Time, quantity of cells, ampere-hour
Real-time display Current, cell voltage, time, stage, mode, Ah, Wh
Time resolution 1 second
Timing accuracy ±10 seconds/24 hours
Stage time range 1 second - 1000 hours
Stage setting range 1-200 stages
Discharge voltage range Customizable (minimum 1.5V per battery)
Total current range 0A to customizable maximum
Current accuracy ±0.5% F.S (1%-100% range)
Voltage sampling 20 points per channel, 0V-5V range, ±0.5% accuracy
Communication RS485 to PC, USB/serial connection, supports 200 channels per PC
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment 0
Front view of the discharge testing machine
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment 1
Detailed view of battery connection interface
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment 2
Operation panel and control interface

連絡先の詳細
DONGGUAN LONROY EQUIPMENT CO LTD

コンタクトパーソン: Kaitlyn Wang

電話番号: 19376687282

ファックス: 86-769-83078748

私達に直接お問い合わせを送信 (0 / 3000)