logo
Casa ProdottiMacchina di prova di laboratorio

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

Certificazione
Porcellana DONGGUAN LONROY EQUIPMENT CO LTD Certificazioni
Porcellana DONGGUAN LONROY EQUIPMENT CO LTD Certificazioni
Sono ora online in chat

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

Grande immagine :  Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

Dettagli:
Luogo di origine: Cina
Marca: Lonroy
Certificazione: ISO ASTM CE
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1
Prezzo: Negotaible
Imballaggi particolari: pacchetto di legno
Tempi di consegna: 5-8 giorni di lavoro
Termini di pagamento: L/C, D/A, D/P, T/T, Western Union
Capacità di alimentazione: 200

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

descrizione
Voltaggio: 220 V, 380 V. Classe di protezione: IP56
Risoluzione di tempo: 1 secondo Precisione di temporizzazione: ± 10 secondi / 24 ore
Gamma di palcoscenici: 1 - 200 fasi Conteggio del ciclo: Massimo 65535
Modalità di lavoro: Scarico di corrente costante, scarico di potenza costante, scarico di resistenza costante, scarico i Tempo di scena: 1 secondo - 1000 ore
Intervallo record: 1 secondo - 1000 ore Nidificazione del ciclo: Massimo 6 strati
Tensione di scarico: *V ~*V. Intervallo di corrente totale: 0a ~*a
Precisione attuale: ± 0,5% fs Risoluzione corrente: 0.01A
accuratezza di tensione: ± 0,5% fs
Evidenziare:

IP56 Protection Battery Discharge Testing Machine

,

220V Voltage Single Cell Recovery Discharge Equipment

,

380V Voltage Recycling Discharge Device

Battery Recovery Discharge Testing Machine Single Cell Recovery Discharge Equipment Recycling Discharge Device
This advanced battery recovery discharge testing machine is designed for efficient discharge processes during lithium-ion battery recycling operations. The equipment features customizable configurations and intelligent discharge management for optimal performance.
Specifications and Components
  • Each unit consists of customizable main channels (quantity adjustable per requirements)
  • Complete set includes discharge main channels, battery racks, connection lines, and clamps
  • Versatile crocodile clip battery clamps compatible with both cylindrical and pouch batteries
Equipment Features and Capabilities
Application Scope
Primarily designed for discharge processes in single lithium-ion battery recycling operations.
Key Functions
  • Parallel Discharge: Each main channel supports simultaneous connection of 20 batteries with independent operation
  • Safety Protection: Optimized circuit design prevents short circuits, reverse connections, and uncontrolled discharge
  • Intelligent Equalization: Automatic adjustment of discharge current based on battery voltage (up to 20A)
  • Voltage Monitoring: Real-time collection and comparison of battery voltages with dynamic display of highest/lowest values
  • PC Integration: Full equipment control via upper computer software with detailed voltage monitoring
  • Safety Checks: Automatic battery presence detection (0.5V threshold) with alarm system for contact faults
  • Data Recording: Automatic generation of termination data when batteries reach set voltage thresholds
Technical Specifications
Parameter Specification
Main channels per cabinet Customizable quantity
Auxiliary channels per main channel 20 units
Energy consumption Discharge energy converted to heat via electronic load
Working modes Constant current, constant power, constant resistance, multi-stage, cyclic discharge
Stage termination conditions Time, quantity of cells, ampere-hour
Real-time display Current, cell voltage, time, stage, mode, Ah, Wh
Time resolution 1 second
Timing accuracy ±10 seconds/24 hours
Stage time range 1 second - 1000 hours
Stage setting range 1-200 stages
Discharge voltage range Customizable (minimum 1.5V per battery)
Total current range 0A to customizable maximum
Current accuracy ±0.5% F.S (1%-100% range)
Voltage sampling 20 points per channel, 0V-5V range, ±0.5% accuracy
Communication RS485 to PC, USB/serial connection, supports 200 channels per PC
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment 0
Front view of the discharge testing machine
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment 1
Detailed view of battery connection interface
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment 2
Operation panel and control interface

Dettagli di contatto
DONGGUAN LONROY EQUIPMENT CO LTD

Persona di contatto: Kaitlyn Wang

Telefono: 19376687282

Fax: 86-769-83078748

Invia la tua richiesta direttamente a noi (0 / 3000)