logo
제품 소개실험실 검사 기계

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

인증
중국 DONGGUAN LONROY EQUIPMENT CO LTD 인증
중국 DONGGUAN LONROY EQUIPMENT CO LTD 인증
제가 지금 온라인 채팅 해요

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

큰 이미지 :  Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

제품 상세 정보:
원래 장소: 중국
브랜드 이름: Lonroy
인증: ISO ASTM CE
결제 및 배송 조건:
최소 주문 수량: 1
가격: Negotaible
포장 세부 사항: 나무 패키지
배달 시간: 5-8 일
지불 조건: L/C, D/A, D/P, T/T, Western Union
공급 능력: 200

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

설명
전압: 220 V, 380 v 보호 수업: IP56
시간 해상도: 1 초 타이밍 정확도: ± 10 초 / 24 시간
무대 범위: 1-200 단계 사이클 수: 최대 65535
작업 모드: 일정한 전류 방전, 일정한 전력 방전, 일정한 저항 방전, 다단방 방전, 다단계 순환 방전, 정지, 일시 정지 단계 시간: 1 초 - 1000 시간
기록 간격: 1 초 - 1000 시간 사이클 중첩: 최대 6 층
방전 전압: *V ~*v 총 현재 범위: 0a ~*a
현재 정확도: ± 0.5% fs 현재 분석: 0.01A
전압 정확도: ± 0.5% fs
강조하다:

IP56 Protection Battery Discharge Testing Machine

,

220V Voltage Single Cell Recovery Discharge Equipment

,

380V Voltage Recycling Discharge Device

Battery Recovery Discharge Testing Machine Single Cell Recovery Discharge Equipment Recycling Discharge Device
This advanced battery recovery discharge testing machine is designed for efficient discharge processes during lithium-ion battery recycling operations. The equipment features customizable configurations and intelligent discharge management for optimal performance.
Specifications and Components
  • Each unit consists of customizable main channels (quantity adjustable per requirements)
  • Complete set includes discharge main channels, battery racks, connection lines, and clamps
  • Versatile crocodile clip battery clamps compatible with both cylindrical and pouch batteries
Equipment Features and Capabilities
Application Scope
Primarily designed for discharge processes in single lithium-ion battery recycling operations.
Key Functions
  • Parallel Discharge: Each main channel supports simultaneous connection of 20 batteries with independent operation
  • Safety Protection: Optimized circuit design prevents short circuits, reverse connections, and uncontrolled discharge
  • Intelligent Equalization: Automatic adjustment of discharge current based on battery voltage (up to 20A)
  • Voltage Monitoring: Real-time collection and comparison of battery voltages with dynamic display of highest/lowest values
  • PC Integration: Full equipment control via upper computer software with detailed voltage monitoring
  • Safety Checks: Automatic battery presence detection (0.5V threshold) with alarm system for contact faults
  • Data Recording: Automatic generation of termination data when batteries reach set voltage thresholds
Technical Specifications
Parameter Specification
Main channels per cabinet Customizable quantity
Auxiliary channels per main channel 20 units
Energy consumption Discharge energy converted to heat via electronic load
Working modes Constant current, constant power, constant resistance, multi-stage, cyclic discharge
Stage termination conditions Time, quantity of cells, ampere-hour
Real-time display Current, cell voltage, time, stage, mode, Ah, Wh
Time resolution 1 second
Timing accuracy ±10 seconds/24 hours
Stage time range 1 second - 1000 hours
Stage setting range 1-200 stages
Discharge voltage range Customizable (minimum 1.5V per battery)
Total current range 0A to customizable maximum
Current accuracy ±0.5% F.S (1%-100% range)
Voltage sampling 20 points per channel, 0V-5V range, ±0.5% accuracy
Communication RS485 to PC, USB/serial connection, supports 200 channels per PC
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment 0
Front view of the discharge testing machine
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment 1
Detailed view of battery connection interface
Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment 2
Operation panel and control interface

연락처 세부 사항
DONGGUAN LONROY EQUIPMENT CO LTD

담당자: Kaitlyn Wang

전화 번호: 19376687282

팩스: 86-769-83078748

회사에 직접 문의 보내기 (0 / 3000)