logo
제품 소개열 분석기

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

인증
중국 DONGGUAN LONROY EQUIPMENT CO LTD 인증
중국 DONGGUAN LONROY EQUIPMENT CO LTD 인증
제가 지금 온라인 채팅 해요

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester
ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

큰 이미지 :  ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

제품 상세 정보:
원래 장소: 광동, 중국
브랜드 이름: lonroy
결제 및 배송 조건:
최소 주문 수량: 1

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

설명
힘: 1kw 전압: 220V
측정 시간: 15-20분 플레이트 간격: 0 ~ 160mm
열전도율 범위: 0.00001 ~ 10W/mk, 0.001 ~ 300W/mk 측정 정확도: 3%(국산), 1%(수입)
샘플 크기: 50×50 ~ 300×300mm 뜨거운 표면 온도: 실온 ~ 199.9°C
차가운 표면 온도: 0~99.9℃ 온도 제어 정확도: 0.1ºC
열전도 영역: 150×150mm 열 흐름 매개변수: 23.26w/m2.mV
보호 수업: IP56 재료 호환성: 고체, 분말
제어 방법: 양방향 SCR
강조하다:

ASTM C518 thermal conductivity tester

,

plate heat flow meter

,

DRPL-II thermal analyzer

ASTM C518 DRPL-II Plate Heat Flow Meter High Quality Thermal Conductivity Tester
Product Description

The DRPL-II thermal conductivity tester (plate heat flow meter method) uses the internationally recognized heat flow meter method to detect thermal conductivity and thermal resistance, with computer-controlled automatic detection and report generation.

The instrument applies stable hot surface temperature to one side of the sample, transferring heat to the cold surface (room temperature) through the sample, then measures the heat transfer to calculate thermal conductivity and resistance.

Key Features
  • Simple, quick and repeatable testing method
  • Ideal for research and development of heat transfer in metal materials
  • Suitable for testing plastics, rubber, graphite, insulation materials, aerogel plates, vacuum glass, and more
  • Widely used in universities, research institutes, quality inspection, and industrial applications
  • Complies with GB/T10295-2008 and ASTM C518-04 standards
Technical Specifications
Parameter Specification
Thermal Conductivity Range 0.00001 ~ 10W/m.k, 0.001 ~ 300W/m.k
Measurement Accuracy 3% (domestic heat flow meter); 1% (imported heat flow meter)
Sample Size 50×50 ~ 300×300 (mm), round or square. Custom sizes available
Measurement Time 15-20 minutes
Hot Surface Temperature Room temperature ~ 199.9°C (standard), up to 299.9°C available
Cold Surface Temperature 0 ~ 99.9°C (standard), -10 ~ 99.9°C available
Plate Spacing 0 ~ 160mm adjustable
Heat Transfer Area 150×150mm
Power Supply 220V, 1KW
Additional Features
  • Tests both solid and powder materials
  • Computer-controlled automatic testing with data storage and printing
  • Uses WPY heat flow meter with heat flow parameter 23.26w/m².mV
ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester 0
ASTM C518 DRPL-II Plate Heat Flow Meter
ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester 1
Company Information

연락처 세부 사항
DONGGUAN LONROY EQUIPMENT CO LTD

담당자: Kaitlyn Wang

전화 번호: 19376687282

팩스: 86-769-83078748

회사에 직접 문의 보내기 (0 / 3000)