logo
Startseite ProdukteWärmeanalysator

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

Bescheinigung
CHINA DONGGUAN LONROY EQUIPMENT CO LTD zertifizierungen
CHINA DONGGUAN LONROY EQUIPMENT CO LTD zertifizierungen
Ich bin online Chat Jetzt

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester
ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

Großes Bild :  ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

Produktdetails:
Herkunftsort: Guangdong, China
Markenname: lonroy
Zahlung und Versand AGB:
Min Bestellmenge: 1

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

Beschreibung
Leistung: 1KW Stromspannung: 220 V
Messzeit: 15-20min Abstand zwischen den Platten: 0 ~ 160 mm
Wärmeleitungsbereich: 0,00001 ~ 10 W/mk, 0,001 ~ 300 W/mk Messgenauigkeit: 3 % (Inland), 1 % (importiert)
Probengröße: 50×50 ~ 300×300mm Heiße Oberflächentemperatur: Raumtemperatur ~ 199,9 °C
Kalte Oberflächentemperatur: 0 ~ 99,9 °C Genauigkeit der Temperaturregelung: 0,1ºC
Wärmeübertragungsfläche: 150×150mm Wärmeflussparameter: 23,26 W/m2.mV
Schutzklasse: IP56 Materialkompatibilität: Feststoffe, Pulver
Kontrollmethode: bidirektionaler SCR
Hervorheben:

ASTM C518 thermal conductivity tester

,

plate heat flow meter

,

DRPL-II thermal analyzer

ASTM C518 DRPL-II Plate Heat Flow Meter High Quality Thermal Conductivity Tester
Product Description

The DRPL-II thermal conductivity tester (plate heat flow meter method) uses the internationally recognized heat flow meter method to detect thermal conductivity and thermal resistance, with computer-controlled automatic detection and report generation.

The instrument applies stable hot surface temperature to one side of the sample, transferring heat to the cold surface (room temperature) through the sample, then measures the heat transfer to calculate thermal conductivity and resistance.

Key Features
  • Simple, quick and repeatable testing method
  • Ideal for research and development of heat transfer in metal materials
  • Suitable for testing plastics, rubber, graphite, insulation materials, aerogel plates, vacuum glass, and more
  • Widely used in universities, research institutes, quality inspection, and industrial applications
  • Complies with GB/T10295-2008 and ASTM C518-04 standards
Technical Specifications
Parameter Specification
Thermal Conductivity Range 0.00001 ~ 10W/m.k, 0.001 ~ 300W/m.k
Measurement Accuracy 3% (domestic heat flow meter); 1% (imported heat flow meter)
Sample Size 50×50 ~ 300×300 (mm), round or square. Custom sizes available
Measurement Time 15-20 minutes
Hot Surface Temperature Room temperature ~ 199.9°C (standard), up to 299.9°C available
Cold Surface Temperature 0 ~ 99.9°C (standard), -10 ~ 99.9°C available
Plate Spacing 0 ~ 160mm adjustable
Heat Transfer Area 150×150mm
Power Supply 220V, 1KW
Additional Features
  • Tests both solid and powder materials
  • Computer-controlled automatic testing with data storage and printing
  • Uses WPY heat flow meter with heat flow parameter 23.26w/m².mV
ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester 0
ASTM C518 DRPL-II Plate Heat Flow Meter
ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester 1
Company Information

Kontaktdaten
DONGGUAN LONROY EQUIPMENT CO LTD

Ansprechpartner: Kaitlyn Wang

Telefon: 19376687282

Faxen: 86-769-83078748

Senden Sie Ihre Anfrage direkt an uns (0 / 3000)