logo
Αρχική Σελίδα ΠροϊόνταΘερμικός αναλυτής

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester
ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

Μεγάλες Εικόνας :  ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

Λεπτομέρειες:
Τόπος καταγωγής: Guangdong, Κίνα
Μάρκα: lonroy
Πληρωμής & Αποστολής Όροι:
Ποσότητα παραγγελίας min: 1

ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester

περιγραφή
Εξουσία: 1kW Δυναμικό: 220V
Χρόνος μέτρησης: 15-20 λεπτά Διαχωρισμός πλάκας: 0 ~ 160mm
Πεδίο θερμικής αγωγιμότητας: 0.00001 ~ 10W/MK, 0.001 ~ 300W/MK Ακρίβεια μέτρησης: 3% (εγχώρια), 1% (εισαγόμενος)
Μέγεθος δείγματος: 50 × 50 ~ 300 × 300mm θερμή θερμοκρασία επιφάνειας: θερμοκρασία δωματίου ~ 199.9 ° C
Ψυχρή θερμοκρασία επιφάνειας: 0 ~ 99,9 ° C Ακρίβεια ελέγχου θερμοκρασίας: 0,1ºC
Περιοχή μεταφοράς θερμότητας: 150×150mm Παράμετρος ροής θερμότητας: 23.26W/M2.MV
Κλάση προστασίας: IP56 Συμβατότητα με υλικό: Στερεά, σκόνες
Μέθοδος ελέγχου: αμφίδρομη SCR
Επισημαίνω:

ASTM C518 thermal conductivity tester

,

plate heat flow meter

,

DRPL-II thermal analyzer

ASTM C518 DRPL-II Plate Heat Flow Meter High Quality Thermal Conductivity Tester
Product Description

The DRPL-II thermal conductivity tester (plate heat flow meter method) uses the internationally recognized heat flow meter method to detect thermal conductivity and thermal resistance, with computer-controlled automatic detection and report generation.

The instrument applies stable hot surface temperature to one side of the sample, transferring heat to the cold surface (room temperature) through the sample, then measures the heat transfer to calculate thermal conductivity and resistance.

Key Features
  • Simple, quick and repeatable testing method
  • Ideal for research and development of heat transfer in metal materials
  • Suitable for testing plastics, rubber, graphite, insulation materials, aerogel plates, vacuum glass, and more
  • Widely used in universities, research institutes, quality inspection, and industrial applications
  • Complies with GB/T10295-2008 and ASTM C518-04 standards
Technical Specifications
Parameter Specification
Thermal Conductivity Range 0.00001 ~ 10W/m.k, 0.001 ~ 300W/m.k
Measurement Accuracy 3% (domestic heat flow meter); 1% (imported heat flow meter)
Sample Size 50×50 ~ 300×300 (mm), round or square. Custom sizes available
Measurement Time 15-20 minutes
Hot Surface Temperature Room temperature ~ 199.9°C (standard), up to 299.9°C available
Cold Surface Temperature 0 ~ 99.9°C (standard), -10 ~ 99.9°C available
Plate Spacing 0 ~ 160mm adjustable
Heat Transfer Area 150×150mm
Power Supply 220V, 1KW
Additional Features
  • Tests both solid and powder materials
  • Computer-controlled automatic testing with data storage and printing
  • Uses WPY heat flow meter with heat flow parameter 23.26w/m².mV
ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester 0
ASTM C518 DRPL-II Plate Heat Flow Meter
ASTM C518 DRPL-II Plate Heat Flow Meter HIgh Quality Thermal Conductivity Tester 1
Company Information

Στοιχεία επικοινωνίας
DONGGUAN LONROY EQUIPMENT CO LTD

Υπεύθυνος Επικοινωνίας: Kaitlyn Wang

Τηλ.:: 19376687282

Φαξ: 86-769-83078748

Στείλετε το ερώτημά σας απευθείας σε εμάς (0 / 3000)

Άλλα προϊόντα