logo
Home Products

DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument

Certification
China DONGGUAN LONROY EQUIPMENT CO LTD certification
China DONGGUAN LONROY EQUIPMENT CO LTD certification
I'm Online Chat Now

DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument

DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument
DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument

Large Image :  DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument

Product Details:
Place of Origin: Guangdong, China
Brand Name: lonroy
Payment & Shipping Terms:
Minimum Order Quantity: 1

DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument

Description
Accuracy: ±3% Voltage: 220 V
Power Supply: 220V, 50HZ Relative Humidity: ≤80%
Protection Class: IP57 Thermal Conductivity Range: 0.001 To 10w/m.k
Thermal Storage Coefficient: 0.1-100W/m2K Thin Specimen Size: 20×20× (1.5 ~ 3) Cm
Thick Specimen Size: 20×20× (4 ~ 10) Cm Ambient Temperature: 10 ~ 35ºC
Test Speed: ~10 Minutes Per Test Measurement Output: Computer Automatic Testing, Data Printing Output
Material Compatibility: Insulation Materials, Concrete, Plastic, Rubber, Graphite Measurement Parameters: Thermal Conductivity, Heat Storage Coefficient, Thermal Conductivity Coefficient, Specific Heat
Wet State Capability: Can Measure Thermal Properties Under Different Wet Conditions
Highlight:

DRM-II thermal conductivity instrument

,

Non-steady state conductometer

,

Thermal analyzer measuring instrument

DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument
Product Description
The DRM-II thermal conductivity measuring instrument is a non-steady state method conductometer designed for accurate and efficient thermal property measurements.
Key Features
  • Simple device setup with high accuracy measurements
  • Fast testing speed (approximately 10 minutes per test)
  • Simultaneous measurement of thermal conductivity, heat storage coefficient, thermal conductivity coefficient, and specific heat
  • Capability to measure thermal physical properties at different moisture states
  • Compliance with multiple industry standards including JGJ/T12-2019, JG158-2004, and JG/T283-2010
  • Suitable for various materials including insulation materials, concrete, plastics, rubber, and graphite
Technical Specifications
Parameter Specification
Application Scope Determines thermal conductivity, thermal storage coefficient, thermal conductivity coefficient and specific heat of homogeneous plates, gels, powders and granular materials under dry or different wet conditions
Measurement Range Thermal conductivity: 0.001 to 10 W/m·K
Thermal storage coefficient: 0.1-100 W/m²·K
Sample Size Thin specimen: 20×20×(1.5-3) cm
Thick specimens: 20×20×(4-10) cm
Power Supply 220V, 50Hz
Working Conditions Ambient temperature: 10-35°C
Relative humidity: ≤80%
Measurement Accuracy ±3%
Data Output Computer automatic testing with data printing output
Measurement Principle
The DRM-II thermal conductivity measuring instrument operates on the non-steady state thermal conductivity principle. It applies short-term heating to the test material, causing temperature changes. By analyzing these temperature variations and solving the thermal conductivity differential equation, the instrument calculates the thermal conductivity coefficient, thermal conductivity coefficient, and specific heat of the test material.
DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument 0
DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument
DRM-II Non-steady State Method Conductometer Thermal Conductivity Measuring Instrument 1
Company Information

Contact Details
DONGGUAN LONROY EQUIPMENT CO LTD

Contact Person: Kaitlyn Wang

Tel: 19376687282

Fax: 86-769-83078748

Send your inquiry directly to us (0 / 3000)