Product Details:
|
Power Supply: | AC 220V, 50 Hz | Measurement Accuracy: | ±5% |
---|---|---|---|
Relative Humidity: | ≤80% RH | Temperature Stability: | ≤±1.5°C |
Warranty: | 1 Year | Certification: | Includes Calibration Certification |
LRY-II Thermal Effusivity Analyzer Thermal Property Measurement Machine
1.Description:
This instrument can simultaneously measure the heat storage coefficient, thermal conductivity, thermal diffusivity and specific heat of materials under different moisture contents in a single test. The device is simple, highly accurate and has a fast testing speed (about ten minutes for a single test).
2.Standard:
JGJT 12-2019 (replacing JGJ 51-2002) (Light Aggregate Concrete Technical Code), JG158-2004 "Adhesive Powder Polystyrene Granule External Wall External Insulation System", and Appendix B of JG/T283-2010 "Expanded Porous Microsphere Lightweight Mortar" regarding the determination of the heat storage coefficient, the requirements of JG/T511-2017 "Building Insulation Ceramic Insulation Board" Appendix A for the test method of the heat storage coefficient of foamed ceramic insulation board, and the determination method of the heat storage coefficient in GB/T26000-2010 "Expanded Porous Microsphere Insulation and Heat Insulation Mortar".
3.Working Principle
The instrument is based on the principle of non-steady heat conduction. It heats the experimental materials for a short period of time, causing changes in the temperature of the materials. Based on the characteristics of these changes, by solving the heat conduction differential equation, the heat storage coefficient, thermal conductivity, thermal diffusivity and specific heat of the experimental materials can be calculated.
4.Configuration:
Including one LRY-II mainframe, one set of software, one heater, one set of thermocouples, one insulated bucket, and one desktop computer (configured as per the contract).
5.Technical Parameter
Parameter | Specification |
Application Scope | Measures thermal conductivity, thermal effusivity, thermal diffusivity, and specific heat capacity of homogeneous materials in dry or moist states: • Forms: Plates, gels, powders, granules • Thermal Effusivity Range: 0.1–30 W/m²·K • Thermal Conductivity Range: 0.035–1.7 W/m·K |
Sample Specifications | Thin Sample: 20 × 20 × (1.5–3) cm (One piece) Thick Samples: 20 × 20 × (4–10) cm (Two pieces) |
Power Supply | AC 220V, 50 Hz |
Dimensions (L×W×H) | Legacy Model (Split Type): 600 × 450 × 700 mm New Model (Integrated): 340 × 700 × 560 mm |
Operating Conditions | • Ambient Temperature: 10–35°C • Relative Humidity: ≤80% RH • Temperature Stability: ≤±1.5°C |
Measurement Accuracy | ±5% |
Data Interface | PC connectivity with automatic testing, data recording, and print output |
Contact Person: Ms. Kaitlyn Wang
Tel: 19376687282
Fax: 86-769-83078748