Product Details:
|
Frequency Modulation Range (Hz): | 5~500 | Maximum Load: | 600(KG) |
---|---|---|---|
Temperature Range: | -40°C~150°C | Table Size W.D.H (mm): | 550×550×385 |
Total Weight (kg): | 75 | Operation Mode: | Touch Screen Control |
Highlight: | Electromagnetic Vibration Tester,Vertical Vibration Tester |
Electromagnetic Type Vertical Vibration Tester with Closed Loop Function
1. Product overview
Electromagnetic vibration test series are widely applicable to national defense, aerospace, communications, electronics and automobiles
Home appliances and other industries. This type of equipment is used to detect early faults, simulate actual working condition assessment and structural strength test. The product is widely used, with significant test results and high reliability.
1. Humanized operation control, using professional control software control, so that the equipment work more stable, more reliable
2. The whole machine is made of composite industrial materials, precision processing, ultra-quiet.
3. The panel is made of magnesium-aluminum alloy, which can completely isolate the magnetic field interference and effectively prevent the magnetization of the measured object.
4. Sweep frequency and fixed frequency operation modes to meet the testing needs of different industries
5. High-precision frequency output, four-point synchronized excitation, uniform table vibration
6. Strong anti-magnetic and anti-interference capabilities
7. Safe and reliable protection
8. High-efficiency, low-noise fans are used to dissipate heat from the table body to ensure continuous operation for a long time.
9. Vibration with constant amplitude and constant acceleration
10. The system is equipped with high-precision vibration sensors to collect acceleration, amplitude and frequency in real time.
2. Technical parameters
Frequency modulation range (Hz) | 5~500 |
Sweep frequency range (Hz) | 5~500 |
Maximum acceleration (m/s2) | 170 |
Maximum test load (kg) | 40 |
Maximum no-load displacement (mmp-p) | 0~2.5 (automatic adjustment) and 0~5 (manual adjustment) |
Vibration waveform | sine wave |
Vibration axial direction | vertical |
Excitation mode | electromagnetic excitation |
Vibration control mode | closed loop control |
Data acquisition method | vibration data acquisition instrument + acceleration sensor |
Acceleration sensor | 1 (built-in vibration table body) |
3. Sensor parameters
Signal input channel | 1 channel input, the input impedance is greater than 220 k Ω, channel automatically set range, preset the sensitivity of the sensor, the coupling method (DC) |
Resolution | 24-bit A/D converter |
Filter | analog anti-aliasing filter +160dB/oct digital filter to eliminate nonlinear phase distortion and aliasing |
Signal conditioning | charge input, built-in sensor constant current source and charge amplifier. |
SNR | >100 dB |
Operation mode | fixed frequency mode (constant amplitude mode and constant acceleration mode) Sweep mode (constant amplitude scan and constant acceleration scan) Random vibration mode |
Sweep mode | linear |
Operation mode | touch screen control |
Cooling mode | air cooling |
Operating temperature requirements (ºC) | 0~+40 |
Working humidity requirement (%RH) | 0-90, no condensation |
Power requirements | three-phase AC 380V/50Hz ±10% |
System power consumption (KVA) | 5.5 |
Touch screen LCD | 10 "TFT LCD |
Touch screen brightness | 350cd/m2 |
Touch screen color | 65536 colors |
Touch screen resolution | 800*480 |
Table material | magnesium aluminum alloy |
Countertop screw size (standard) | M8 (customizable) |
Number of countertop screws | 8 (customizable) |
Total weight (kg) | 75 |
Table size W.D.H (mm) | 550*550*43 |
Table size W.D.H (mm) | 550*550*385 |
Control cabinet size W.D.H (mm) | 420*300*750 |
4. Technical parameters of vibration controller
Product overview: adopt the international advanced distributed system mechanism system, 32-bit floating point DSP processor, the technical performance of vibration control system will be further improved.
Modular and low noise design technology, independently installed in the control box, USB2.0 and the computer simple connection, based on Windows 8 application software, using adaptive control algorithm control software function is strong.
High control precision, wide dynamic range.
1. the system has a complete automatic safety testing system to protect the normal use of test equipment and specimens.
2. pre-experiment: in the boot state, automatically detect the system loop connection status, indicating the connection status.
3. out-of-tolerance alarm and interruption: the system has automatic out-of-tolerance alarm and interrupt detection automatic protection shutdown
4. the system records the running curve in real time and saves it automatically.
Contact Person: Lilianne Chen
Tel: 13751328225
Fax: 86-769-83078748