logo
ホーム 製品熱分析機

ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester

認証
中国 DONGGUAN LONROY EQUIPMENT CO LTD 認証
中国 DONGGUAN LONROY EQUIPMENT CO LTD 認証
オンラインです

ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester

ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester
ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester

大画像 :  ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester

商品の詳細:
起源の場所: 広東省、中国
ブランド名: LONROY
お支払配送条件:
最小注文数量: 1

ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester

説明
タイプ: テストマシン 精度等級: 高精度
正確さ: ---- 応用: 自動テスト、臨床検査、ラボテスト
カスタマイズされたサポート: OEM、ODM、OBM 力: ---
保護クラス: IP56 電圧: 220V電気機器
保証: 1年 DSCの範囲: ±1000mW
温度範囲: 室温| 1200℃ 温度感度: 0.001°C
加熱速度: 0.1~100°C/分
ハイライト:

ISO 11357 DSC thermal analyzer

,

high-temperature differential scanning calorimeter

,

DSC tester with warranty

ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester 

Product Description

Product Introduction

DSC detects the change in temperature difference (heat flow) between a sample and a reference over time or temperature. The sample and reference are in a homogeneous temperature zone. When there is no thermal change in the sample, the temperatures at both the sample and reference ends change according to a set temperature. When the sample undergoes a change, such as melting, the heat supplied to the sample is used to maintain the melting process, while the reference end temperature continues to rise with the furnace body, resulting in a higher reference end temperature than the sample end temperature, thus creating a temperature difference. This temperature difference change is recorded as a curve, forming the raw DSC data.

 

Technical Features

1. New furnace structure for better baseline and higher accuracy. Heating uses indirect conduction, resulting in high uniformity and stability, reducing pulse radiation, and is superior to traditional heating methods.

2. Ultra-high sensitivity and accuracy; temperature sensitivity can reach 0.001℃, improving measurement accuracy.

3. Two-way control system (host control and software control) for high ease of operation and improved testing efficiency.

4. Automatic switching between two atmosphere flow paths with fast switching speed and short stabilization time. Simultaneously adds a protective gas input.

5. A 7-inch color touchscreen display offers high clarity and comprehensive information.

6. Employs a high-sensitivity constantan sensor, providing high-temperature resistance and corrosion resistance.

7. Allows for multi-segment temperature settings, enabling heating, isothermal control, and cooling according to the temperature testing requirements of different materials.

8. The software records test graphs in real time, analyzes data online, and can directly generate or print reports.

9. Customized instruments can be provided according to user testing needs to meet diverse testing requirements.

ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester 0

                                                             Multi-size crucibles

 

Compliant Standards

GB/T19466.6-2009

GB/T 22232-2008

GS/T19466.2-2004

GB/T19466.3-2004

GB/T23257-2017

HB7614-1998

ISO11357-2:1999

GB/T13663.2

GB/T18742.2, etc., and not limited to the standards listed above. (Partial list of national standards shown)

 

ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester 

Technical Specification

Temperature range

Room temperature ~ 1200℃

DSC range

±1000mw

Temperature sensitivity

0.01℃

Heating rate

0.1~100℃/min

Temperature control method

PID temperature control (heating, constant temperature, cooling)

DSC sensitivity

0.01mw

Data acquisition frequency

33 data points collected per second, multi-point adjustment possible

Cooling method

Air cooling

Isothermal time

Arbitrary setting

Atmosphere device

Built-in gas flow meter with dual gas switching and flow rate control

 

ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester 2ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester 4ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester 6ISO 11357 DSC High-Temperature Differential Scanning Calorimeter High Temp Differential Scanning Calorimetry Tester 8