تفاصيل المنتج:
|
| يكتب: | آلة الاختبار | فئة الدقة: | دقة عالية |
|---|---|---|---|
| دقة: | ---- | طلب: | اختبار السيارات ، الاختبار المختبري ، الاختبار المعملي |
| دعم مخصص: | تصنيع المعدات الأصلية، أوديإم، OBM | قوة: | --- |
| فئة الحماية: | IP56 | الجهد االكهربى: | المعدات الكهربائية 220 فولت |
| ضمان: | 1 سنة | ظروف التشغيل: | درجة الحرارة المحيطة: 10-35 درجة مئوية |
| مزود الطاقة: | 220 فولت ، 50 هرتز | الرطوبة النسبية: | ≥ 80% |
| دقة القياس: | ±3% | ||
| إبراز: | thermal conductivity tester lab equipment,thermal diffusivity test machine,heat pulse method test equipment,thermal diffusivity test machine,heat pulse method test equipment |
||
Heat Pulse Method Thermal Conductivity Tester Thermal Storage Coefficient Test Machine Thermal Diffusivity Test Equipment
Description
The heat pulse method thermal conductivity tester is used to measure the thermal conductivity, thermal storage coefficient, thermal diffusivity, and specific heat capacity of homogeneous plate-like, colloidal, powdered, and granular materials, either dry or at varying moisture levels. It is suitable for testing insulation materials, concrete, plastics, rubber, graphite, and other inorganic materials.
Product Features
The heat pulse method thermal conductivity tester offers simple setup, high accuracy, and fast testing (one test takes approximately ten minutes). It can simultaneously measure a material's thermal conductivity, thermal storage coefficient, thermal diffusivity, and specific heat capacity in a single test, and can also measure thermophysical properties under varying moisture levels.
Reference Standards
JGJ/T 12-2019 "Technical Specification for Lightweight Aggregate Concrete"
JG158-2004 "Glue Powder Polystyrene Granule External Wall Insulation System"
JG/T283-2010 "Expanded Vitrified Microsphere Lightweight Mortar" - Appendix B covers the determination of thermal storage coefficient.
Heat Pulse Method Thermal Conductivity Tester Thermal Storage Coefficient Test Machine Thermal Diffusivity Test Equipment
Technical Specification
|
Thermal Conductivity Test Range |
0.001–10 W/(m²·K) |
|
Thermal Storage Coefficient Test Range |
0.1–100 W/(m²·K) |
|
Specimen Size |
One thin specimen: 20 × 20 × (1.5–3) cm |
|
Two thick specimens |
20 × 20 × (4–10) cm |
|
Power Supply |
220 V, 50 Hz |
|
Operating Conditions |
Ambient Temperature: 10–35 °C |
|
Relative Humidity |
≤ 80% |
|
Measurement Accuracy |
±3% |
|
Control & Output |
Computer-controlled automatic testing and data printout |
![]()
![]()
اتصل شخص: Kaitlyn Wang
الهاتف :: 19376687282
الفاكس: 86-769-83078748