logo
Inicio ProductosMáquina de ensayo de laboratorio

Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine

Certificación
PORCELANA DONGGUAN LONROY EQUIPMENT CO LTD certificaciones
PORCELANA DONGGUAN LONROY EQUIPMENT CO LTD certificaciones
Estoy en línea para chatear ahora

Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine

Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine
Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine

Ampliación de imagen :  Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine

Datos del producto:
Lugar de origen: Cantón, China
Nombre de la marca: LONROY
Pago y Envío Términos:
Cantidad de orden mínima: 1

Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine

descripción
Tipo: Máquina de prueba Clase de precisión: Alta precisión
Exactitud: ---- Solicitud: Pruebas de automóviles, pruebas de laboratorio, pruebas de laboratorio
Soporte personalizado: OEM, ODM, OBM Fuerza: ---
Clase de protección: IP56 Voltaje: Equipo eléctrico de 220 V.
Garantía: 1 año Fuente de alimentación: 220VAC±10%, 50Hz±5% (la fuente de alimentación de 24V requiere mención especial)
Dimensiones: 270 mm (ancho) * 134 mm (alto) * 280 mm (profundidad) Tamaño del orificio de montaje: 230 mm (ancho) * 134 mm (alto)
Peso: Aproximadamente 4 kg.
Resaltar:

NDIR gas analyzer multi-component tester

,

Non-dispersive infrared gas test machine

,

Digital NDIR gas analyzer lab equipment

Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine

Product Description

Production

The LR-G105 infrared gas analyzer is an intelligent industrial online analyzer developed using the NDIR non-dispersive infrared principle combined with new microcomputer technology. The instrument is suitable for use in various non-explosion-proof environments and can analyze and monitor the content of total hydrocarbons, CO, CO2, CH4, and other gases from ppm levels to 99.9% online.

 

The instrument features upper and lower limit alarms, digital and analog outputs, and customizable measurement ranges based on customer requirements and working conditions, providing cost-effective solutions.

 

Typical application areas

Petrochemical, steel and metallurgy, power generation, cement, air separation, chemical, pharmaceutical, bio-fermentation, building materials, new materials, and other industries; including but not limited to online analysis and monitoring of CO, CO2, and other gas content in combustion processes, catalytic cracking reactions, various reaction vessels, storage tanks, process pipelines, combustion furnaces, and exhaust gases.

 

Instrument Features

> Dot matrix LCD display, selectable display units: %, ppm, mg/m³

> Automatic real-time recording of measurement data (≤3000 entries), recorded data displayed in list or curve format

> Arbitrarily settable control points, passive relay output, standard 4-20mA and RS485

> Rich interface options, connectable to DCS and for communication with computers

> Gas path and program design with sensor sealed protection, ensuring stable overall performance

> High cost-effectiveness; the core sensor uses imported products to ensure accurate analysis results, while other components use domestic parts of comparable quality to imported products, significantly reducing the overall price compared to imported instruments.

HDigital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine

Technical Specification

Measurable Gases

CO, CO2, CH4, CnHm (other gases require further discussion)

Analysis Principle

Non-dispersive infrared

Measurement Range

a) CO: 0-2000ppm, 0-2%, 0-5%, 0-10%, 0-20%, 0-50%, 0-100%

b) CO2: 0-2000ppm, 0-2%, 0-5%, 0-10%, 0-20%, 0-50%, 0-100%

c) CH4: 0-2000ppm, 0-5%, 0-20%, 0-100%

Accuracy

≤±1% F.S

Repeatability

≤±0.5% F.S

Stability

≤±0.5% F.S/7d

Response Time

T90 ≤ 15 seconds (depending on the principle and sampling distance)

Operating Environment

Temperature: -25℃~+55℃; Humidity ≤90%RH (non-condensing)

Sample Gas Pressure

0.05 MPa ≤ Inlet pressure ≤ 0.1 MPa (outlet must be at atmospheric pressure)

Sample Gas Flow Rate

400±10 ml/min

Power Supply

220VAC±10%, 50Hz±5% (24V power supply requires special mention)

Data Logging

3000 entries

Output

4~20mA, passive relay, RS485; can communicate with a computer

Operation Method

Button operation

Dimensions

270mm (W) × 134mm (H) × 280mm (D)

Mounting Hole Size

230mm (W) × 134mm (H)

Weight

Approx. 4kg

 

Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine 0Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine 2Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine 4Digital NDIR Non-Dispersive Infrared Gas Analyzer Non-dispersive IR Gas Tester NDIR Multi-component Gas Test Machine 6