Product Details:
|
| Type: | Testing Machine | Accuracy Class: | High Accuracy |
|---|---|---|---|
| Accuracy: | / | Application: | Lab Testing, Laboratory Testing |
| Customized Support: | OEM, ODM, OBM | Power: | / |
| Protection Class: | / | Voltage: | Other |
| Warranty: | 1 Year | ||
| Highlight: | Portable Photosynthesis Fluorescence Measurement System,High Accuracy Photosynthetic Rate Tester,Simultaneous Measurement Chlorophyll Fluorometer |
||
The portable photosynthesis-fluorescence analyzer is the culmination of over a decade of research, development and manufacturing experience, representing a comprehensive upgrade in both performance and technical design. It enables the simultaneous observation and study of plant photosynthesis from the perspectives of both matter and energy.
Distinguished by its exceptional measurement precision, user-friendly design and intuitive visual interface, this instrument stands among the top-tier photosynthesis analyzers produced domestically. In addition to standard photosynthetic measurements — such as photosynthetic rate, transpiration rate, stomatal conductance and intercellular CO₂ concentration — the device captures a range of chlorophyll fluorescence parameters, including Fv, Fv/Fm, Vj, Mo, PIABS, Area and tFm. It also features advanced analytical capabilities such as the generation of photosynthetic response curves and OJIP transient curves.
This instrument is well suited for research in areas including photosynthesis, chlorophyll fluorescence kinetics, stress physiology, soil respiration, and the respiration of fruits and other produce. It has broad applications in the breeding of new agricultural and forestry varieties, the refinement of cultivation practices, ecological and environmental surveys, pollution remediation, the development and utilization of clean energy, landscape gardening, agrometeorological observation and soil restoration.
Inlet/outlet CO₂ concentration, inlet/outlet humidity, temperature, flow rate, leaf temperature, PAR (light intensity) and atmospheric pressure; fluorescence parameters including Fo, Fj, Fi, Fp (Fm), tFm and Area.
Photosynthetic parameters: photosynthetic rate, transpiration rate, stomatal conductance, intercellular CO₂ concentration, instantaneous water-use efficiency, intrinsic water-use efficiency, CO₂ differential, RH differential, CO₂ resistance, vapor pressure deficit (VPD), boundary layer conductance, boundary layer resistance, mesophyll conductance, maximum Rubisco carboxylation efficiency, maximum electron transport rate, CO₂ compensation point and CO₂ saturation point.
Fluorescence parameters: photochemical efficiency parameters (Fv, Fv/Fm, Vt, Vj, Mo, Sm, Ss); quantum yields or energy distribution ratios (φPo, ψo, φEo, φDo); performance indices (PIABS, PICS) and other related fluorescence parameters.
Automatic control of flow rate and light intensity; control of measurement duration; selection between open and closed gas-circuit modes; manual/automatic measurement modes; control of actinic light intensity; automatic calibration.
Photosynthesis curves (photosynthesis vs. light intensity, CO₂, humidity or temperature); rapid fluorescence kinetics curves (OJIP curves).
Real-time display of parameters, measured values, calculated values and system information; bilingual support (Chinese/English); intuitive operational guidance; pump pressure alarm for detecting blockages in the gas circuit.
User-performable firmware upgrades; portable (no-installation-required) data transmission software.
Built-in rechargeable lithium battery with low-voltage alarm.
Photosynthesis module; fluorescence module; photosynthesis curve module; CO₂ measurement module.
Compatible with chambers for plant communities, soil respiration, fruit respiration, seed respiration, algal fluorescence and clustered leaves.
| Type | Non-dispersive infrared (NDIR) analyzer |
|---|---|
| Range | 0–1500 ppm or 0–3000 ppm (selectable) |
| Resolution | 0.1 ppm |
| Accuracy | At constant CO₂ levels, average noise ≤ 0.2 ppm; maximum < 0.5 ppm |
| Category | Silicon photocell with a correction filter |
|---|---|
| Range | 0–3000 μmol m⁻² s⁻¹ |
| Spectral Range | 400–700 nm (visible light range) |
| Resolution | 1 μmol m⁻² s⁻¹ |
| Error | ±2% |
| Type | T-type thermocouple |
|---|---|
| Range | 0–50 °C |
| Resolution | 0.1 °C |
| Error | ±0.3 °C |
Contact Person: Kaitlyn Wang
Tel: 19376687282
Fax: 86-769-83078748