ISO Chemical Oxygen Demand Digestion Tester Water Oxidation Demand Digestive Tester COD Digestive Analyzer COD Digester
Product Background
The standard analytical method HJ828-2017 clearly specifies the determination procedure for chemical oxygen demand (COD Cr) in water, imposing strict requirements on conditions such as heating digestion time, solution acidity, and the dosage of oxidant and catalyst. Therefore, the determination of COD Cr is highly condition-dependent; any deviation from the standard requirements will affect the accuracy of the results.
Product Overview
The HH-1012 COD digester strictly adheres to the basic principles of international standards (ISO) and national standard HJ828-2017, ensuring that the reflux heating and gentle boiling digestion process for 2 hours is completely consistent with the standard method. The preparation and addition of reagents are consistent with the HJ environmental standard method, thus guaranteeing the reliability and accuracy of the analytical results.
This instrument uses microcomputer technology to time the heating furnace, allowing simultaneous heating of 12 250mL Erlenmeyer flasks, achieving energy saving, reduced power load, and improved work efficiency.
|
Item |
Parameters |
|
Applicable Standard |
HJ828-2017 |
|
Measuring Range |
5~700 mg/L; 700~10000 mg/L (measurement after dilution) |
|
Digestion Time |
1 minute ~ 2 hours and 30 minutes (adjustable by users) |
|
Measurement Deviation |
Potassium hydrogen phthalate standard solution (500 mg/L): relative standard deviation ≤5.0%Industrial organic wastewater (500 mg/L): relative standard deviation ≤8.0% |
|
Ambient Temperature |
≤40°C |
|
Cooling Method |
Water cooling with top-mounted thorn-shaped condenser tube plus dual-fan combined cooling |
|
Number of Digestion Samples |
12 pieces of 250 mL conical flasks, heated simultaneously in three rows |
|
Heating Power |
Less than 2800W (AC 220V, 50Hz) |
|
Heating Surface |
Microcrystalline glass heating plate, integral overhead structure for easy replacement and maintenance |
ISO Chemical Oxygen Demand Digestion Tester Water Oxidation Demand Digestive Tester COD Digestive Analyzer COD Digester
Instrument Panel Button Instructions
Button Layout
The panel has 5 buttons: Start, Up, Set, Down, and Fan.
Indicator Light Instructions
The panel has 6 indicator lights: Working, Time, Temperature, Power, Start, and Fan.
Operation Instructions
|
Fan Control |
The fan is on by default after the instrument is reset. The fan can be turned on and off at any time; press once to turn it on, press again to turn it off, and repeat. |
|
Heating Control |
The Start button is only operable when the Working indicator light is on. After reset, the heating device is stopped. Press the Start button once to start heating, press again to stop heating, and repeat. |
|
Parameter Setting |
Press the Set button (it will automatically stop heating if the instrument is heating). The 6 indicator lights will illuminate sequentially |
|
Working Light On |
The Start button is operable; the Up/Down buttons are inactive. |
|
Time Light On |
Adjust the heating time using the Up/Down buttons (each press increases or decreases by 10 minutes), **150 minutes. |
|
Temperature indicator light |
Adjust the heating temperature using the up/down keys (each press increases or decreases by 10℃), maximum 500℃. |
|
Power indicator light |
Adjust the heating power using the up/down keys (each press increases or decreases by 5%), maximum 500℃. |
|
Parameter saving |
The instrument automatically saves the set time, temperature, and power parameters, which are automatically recalled upon next power-on without needing to be re-set. |
|
Display area description |
Front panel display area |
|
Bottom row of numbers |
Current temperature |
|
Top numbers |
Timer duration |
|
Precautions |
Please refer to the national standard analytical method HJ828-2017 for sample processing and analysis methods. |
|
Before using the instrument, please ensure that the power supply and cooling system are working properly to ensure a safe and reliable digestion process.
|
|
![]()
![]()
![]()