Product Details:
|
| Type: | Testing Machine | Accuracy Class: | High Accuracy |
|---|---|---|---|
| Accuracy: | / | Application: | Auto Testing |
| Customized Support: | OEM, ODM, OBM | Power: | --- |
| Protection Class: | Ip56 | Voltage: | 220 V |
| Warranty: | 1 Year | Test Load: | Eight Sets Of Weights |
| Power: | AC220V±10% 50/60HZ | ||
| Highlight: | ISO 1133 melt flow rate tester,ASTM D1238 MVR analyzer,plastic materials MFR testing instrument |
||
ISO 1133 ASTM D1238 Melt Flow Rate Testing Instrument Plastic Materials Melt Volume Flow Rate Tester MFR Analyzer MVR Tester
Description
Melt flow rate testing instrument can be used for ABS, polystyrene, polyethylene, polypropylene, polyamide, fiber resin, acrylate, POM, fluorine plastic, polycarbonate and other plastic materials, the melt flow rate (MFR) or the melt volume flow rate (MVR) to be determined.
Standard
GB/T3682-2018,ISO1133-2011, ASTM D1238
Test Methods:MFR Methods
Display Mode:English color touch screen display
ISO 1133 ASTM D1238 Melt Flow Rate Testing Instrument Plastic Materials Melt Volume Flow Rate Tester MFR Analyzer MVR Tester
Technical Specification
|
Model |
LR-A001-A |
|
Barrel parameters |
Inner hole 9.550±0.005mm |
|
Pistons parameters |
Piston head: 9.474±0.005mm |
|
Outlet length |
8.000±0.025mm |
|
Paramters |
Extrusion hole 1=2.095±0.005mm |
|
Temperature parameter |
With intelligent temperature control instrument, with four pairs of significant temperature setting control, PID parameters can be automatically set, precision up to ± 0.1 degree centigrade |
|
Temperature range |
Room Temperature~450degree centigrade |
|
Temperature fluctuation |
±0.2 ℃ |
|
Temperature uniformity |
±1℃ |
|
Temperature display resolution |
0.1 ℃ |
|
Display resolution |
0.1 ℃ |
|
Maximum comsuption |
< 600W |
|
Time display resolution |
0.1s |
|
Weight parameters are as follows: |
|
|
Weight accuracy |
±0.5% |
|
Basic configuration |
A 0.325kg |
|
B 1.2kg |
|
|
C 2.16kg |
|
|
D 3.8kg |
|
|
E 5kg |
|
|
|
|
|
F 10kg |
|
|
|
|
|
G 12.5kg |
|
|
H 21.6kg |
|
|
|
|
|
Position detection |
|
|
Loop distance from up and down |
30mm |
|
Control precision |
± 0.1mm |
|
Test flow control |
|
|
Times of cutting the material |
0~ 10 times |
|
Material cutting interval |
0~999s(set reference Table 2) |
|
Control flow reaches the set temperature without volatility |
|
|
Output mode |
Micro-automatic print output |
|
Cut material methods |
The hand automatic cut into one body |
|
Test load |
Eight sets of weights |
|
Power |
AC220V±10% 50/60HZ |
![]()
![]()
![]()
![]()
![]()
![]()
![]()