logo
Home ProductsDifferential Scanning Calorimeter

DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration

Certification
China DONGGUAN LONROY EQUIPMENT CO LTD certification
China DONGGUAN LONROY EQUIPMENT CO LTD certification
I'm Online Chat Now

DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration

DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration
DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration

Large Image :  DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration

Product Details:
Place of Origin: Guangdong, China
Brand Name: lonroy
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: $22,000

DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration

Description
Customized Support: OEM, ODM, OBM Warranty: 1 Year
Gas Flow: 0-300ml /min Power Supply: AC220V/50Hz Or Customized
DSC Sensitivity: 0.001mW Constant Temperature Time: 0~400
Highlight:

DSC 300 differential scanning calorimeter with liquid nitrogen refrigeration

,

Differential scanning calorimeter melting measurement machine

,

DSC 300 calorimeter -170~600C temperature range

DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration 

 DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration 0

DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration 

Product Introduction:  

The differential scanning calorimeter is touch-screen and can be used for glass transition temperature measurement, phase transition measurement, melting and enthalpy measurement  

Value test, product stability, oxidation induction period test, specific heat test, etc.  Mainly used in chemical, energy, metallurgy, mineral, polymer materials, metal materials and other industries  

Technical parameters:  

1. Temperature range: -170~600℃, liquid nitrogen refrigeration  

2 temperature resolution: 0.01℃  

3 temperature fluctuation: ±0.01℃  

4. Temperature repeatability: ±0.1℃  

5. Heating rate: 0.1 ~ 80℃/min  

6. Constant temperature time: 0~400  

7. Temperature control mode: heating, cooling, constant temperature  

8.DSC range: 0 ~ ±600mW  

9.DSC resolution: 0.001mW  

10.DSC sensitivity: 0.001mW  

11. Power supply: AC220V/50Hz or customized  

12. Cooling equipment: liquid nitrogen cooling  

13. Atmosphere control gas: nitrogen, oxygen (automatic instrument switch)  

14. Gas flow: 0-300ml /min  

15 gas pressure: 0.2mpa  

16. Display mode: 24bit color, 7 inch LCD touch screen display  

17. Data interface: standard USB interface  

18. Parameter standard: equipped with standard material (indium, tin), users can adjust the temperature  

19. Upper computer operation software, coordinate range automatically switch, no manual adjustment;  Software analysis results can be dragged at will display position  

20. The instrument has multiple groups of thermocouples, one group to test the sample temperature, one group to test the internal environment temperature of the instrument, and one group to test the furnace temperature  

 

 

Technical features:  

1. Industrial grade 7 inch touch screen, display rich information.  

2. New furnace body structure, can be matched with a variety of refrigeration devices.  

3.USB communication interface, strong commonality, reliable communication without interruption, support self-recovery connection function.  

4. Automatic switching of two air flow, fast switching speed, short stability time.  At the same time, a protective gas input is added.  

5. Software is simple and easy to operate.  


 
 DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration 2

Configuration list

 

serial number

 name of the accessories  

quantity  

note  

1

Differential instrument  

1  

 

2

The software U disk  

1 only  

 

3

Communication data line  

2 the root  

USB data communication  

4

The power cord  

1 the root  

 

5

Aluminum crucible  

200 only  

 

6

Porcelain crucible  

100 only  

Used for testing corrosive samples  

7

Furnace cover  

3 only  

Multilayer insulation  

8

Raw tape  

Volume 1  

 

9

Standard material  

One copy each of the  

Indium, tin,  

10

10 A fuse  

5 only  

 

 11

Sample spoon/sample press/tweezers  

Each one  

 

12

Dust cleaning ball  

1  

 

13

Air pipe (including joint)  

2 the root  

Φ8mm

14

Instruction book, warranty card, certificate of quality  

One copy each of the  

 

15

Fully automatic liquid nitrogen tank  

1 set of  

 

 

 

 

DSC 300 Differential Scanning Calorimeter Melting Measurement Machine -170~600C Liquid Nitrogen Refrigeration 4

Contact Details
DONGGUAN LONROY EQUIPMENT CO LTD

Contact Person: Kaitlyn Wang

Tel: 19376687282

Fax: 86-769-83078748