logo
Home ProductsLab Test Machine

NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester

Certification
China DONGGUAN LONROY EQUIPMENT CO LTD certification
China DONGGUAN LONROY EQUIPMENT CO LTD certification
I'm Online Chat Now

NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester

NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester
NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester

Large Image :  NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester

Product Details:
Place of Origin: Guangdong, China
Brand Name: LONROY
Payment & Shipping Terms:
Minimum Order Quantity: 1

NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester

Description
Type: Testing Machine Accuracy Class: High Accuracy
Accuracy: ---- Application: Auto Testing, Laboratory Testing, Lab Testing
Customized Support: OEM, ODM, OBM Power: ---
Protection Class: Ip56 Voltage: 220V Electrical Equipment
Warranty: 1 Year Data Logging: 10000 Entries
Dimensions: 485mm (W) * 177mm (H) * 365mm (D); Standard 19" 4U Mounting Hole Dimensions: 445mm (W) * 177mm (H)
Weight: Approximately 10 Kg
Highlight:

NDIR gas analyzer high sensitivity

,

infrared gas tester LCD touch screen

,

hydrocarbons content tester lab machine

NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester

Product Description

Product Introduction

The LR-G104 infrared gas analyzer is an intelligent industrial online analyzer developed using the NDIR non-dispersive infrared principle combined with new microcomputer technology. The instrument is suitable for use in various non-explosion-proof environments and can online analyze and monitor the content of total hydrocarbons, CO, CO2, CH4, and other gases from ppm levels to 99.9%.

 

The instrument features a 7-inch LCD touch screen, upper and lower limit alarms, and digital and analog outputs.  The measurement range can be customized according to customer requirements and working conditions, providing a cost-effective solution.

 

Typical Application Areas

Petrochemical, steel and metallurgy, power generation, cement, air separation, chemical, pharmaceutical, bio-fermentation, building materials, new materials, and other industries; including but not limited to online analysis and monitoring of CO and CO2 gas content in combustion processes, catalytic cracking reactions, various reaction vessels, storage tanks, process pipelines, combustion furnaces, and exhaust gases.

 

Instrument Features

> 7-inch LCD touch screen, simple and convenient operation, selectable display units: %, ppm, mg/m³

> Automatic real-time recording of measurement data (10,000 entries), data displayed in list or curve format

> Arbitrarily settable control points, passive relay output, standard 4-20mA and RS485

> Rich interface options, connectable to DCS and for communication with computers

> Gas path and program design with sensor sealed protection, stable overall performance

> High cost-effectiveness; the core sensor uses imported products to ensure accurate analysis results, while other components use domestic parts of comparable quality to imported products, significantly reducing the overall price compared to imported instruments.

HNDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester

Technical Specification

Measurable Gases

CO, CO2, CH4, CnHm (other gases require further discussion)

Analysis Principle

Non-dispersive infrared

Measurement Range

CO: 0-10/100/1000/2000 ppm, 0-2%, 0-5%, 0-10%, 0-20%, 0-50%, 0-100%

CO2: 0-10/100/1000/2000 ppm, 0-2%, 0-5%, 0-10%, 0-20%, 0-50%, 0-100%

CH4: 0-10/100/1000/2000 ppm, 0-5%, 0-20%, 0-100%

Note: Other ranges and gases can be customized according to customer requirements

Accuracy

≤±1% F.S

Repeatability

≤±0.5% F.S

Stability

≤±0.5% F.S/7d

Response Time

T90 ≤ 15 seconds (depending on the principle and sampling distance)

Operating Environment

Temperature: -25℃~+55℃; Humidity ≤90%RH (non-condensing)

Sample Gas Pressure

0.05 MPa ≤ Inlet pressure ≤ 0.1 MPa (outlet must be at atmospheric pressure)

Sample Gas Flow Rate

400±10 ml/min

Power Supply

220VAC±10%, 50Hz±5% (24V power supply requires special mention)

Data Logging

10000 entries

Output

4~20mA, passive relay, RS485; can communicate with a computer

Operation Method

Touch screen

Dimensions

485mm (W) × 177mm (H) × 365mm (D); Standard 19" 4U

Mounting Hole Dimensions

445mm (W) × 177mm (H)

Weight

Approximately 10 kg

 

NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester 0NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester 2NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester 4NDIR Non-Dispersive Infrared Gas Analyzer High Sensitivity LCD Touch Screen Total Hydrocarbons Content Tester 6