Product Details:
|
| Voltage: | 220 V | Protection Class: | Ip56 |
|---|---|---|---|
| Storage Space: | More Than 300G | Burette Resolution: | 1/48,000 |
| Titration Cup Capacity: | 250mL | Titration Volume Accuracy: | 0.001 ML |
| Measurement Range MV: | -2000.0 MV To +2000.0 MV | Measurement Range PH: | -20.000 To +20.000 PH |
| Measurement Range KOH: | 0.05 - 100 Mg KOH Per Gram | PH Resolution: | 0.001 PH |
| PH Accuracy: | 0.003 PH | Temperature Range: | -5 To 120 Degrees Celsius |
| Temperature Accuracy: | ±0.1℃ | Communication Ports: | 2 USB Ports, 232 Serial Ports, Ethernet |
| Liquid Addition Channels: | 2 Sets (expandable To 8 Channels) | ||
| Highlight: | 300G Storage Fatty Acid Value Analyzer,1/48,000 Resolution Fatty Acid Value Tester,220V Voltage Acid-base Titration Machine |
||
Fatty Acid Value Analyzer Automatic Fatty Acid Value Determination Machine Acid-base Titration Method Fatty Acid Value Tester
Key Innovation Points
Includes a 2-channel liquid addition module. It can also be equipped with a 16/18/20 station rotary automatic sampler.
It can drive two liquid addition module units, and the burette and pipeline should be resistant to acids, alkalis and corrosion.
Imported corrosion-resistant polytetrafluoroethylene rotary valve, PTFE corrosion-resistant titration tube, high-power stirring table, achieving magnetic stirring through coils.
High-precision closed-loop control ensures precise titration.
The liquid addition resolution of the burette is 1 uL.
High-precision burette is accurate to 0.003 ML.
Automatically check the instrument status upon startup
The entire pipeline is designed with a fully sealed structure, making it easy and quick to replace.
Real-time display of titration curves and measurement results, facilitating operation
Support various titration methods such as acid-base titration, redox titration, precipitation titration, complexation titration, and non-aqueous titration.
Compliant with GMP standards, the titration results meet GLP requirements.
Automatic sample loading, automatic pipeline cleaning, automatic measurement of experimental results, automatic recording and drawing of the real-time change curve of pH - titration volume during titration.
Compliant with the 2020 edition of the pharmacopoeia
It has comprehensive multi-level user permission management functions, enabling the functions of audit tracking and permission management.
Application fields
Acid-base titration, for example: content of oxalic acid (aqueous phase/non-aqueous phase)
Redox titration, for example: iodine value, iron (II) content
Precipitation titration, for example: Chloride content
Complexometric titration, for example: calcium content,
Titration using polarized electrodes (Ipol, Upol)
Fatty Acid Value Analyzer Automatic Fatty Acid Value Determination Machine Acid-base Titration Method Fatty Acid Value Tester
Technical Specification
|
Measurement Range |
-2000.0 mV to +2000.0 mV;-20.000 to +20.000 pH;0.05 - 100 mg KOH per gram |
|
Measurement Resolution (mV) |
Resolution: 0.1 mV; Accuracy: 0.1 mV ± 0.03% |
|
Measurement Resolution (KOH) |
0.02 mg of KOH per gram |
|
pH Measurement |
Resolution: 0.001 pH; Accuracy: 0.003 pH |
|
Titration Volume Accuracy |
0.001 mL |
|
Measurement Mode |
- MEAS: Measurement of pH/mV/T - CAL: pH calibration (multiple points) - SET: Sets the end-point mode - MET: Equal volume titration - DET: Dynamic Titration |
|
Titration Mode |
Acid-base titration, redox titration, precipitation titration, complexation titration, non-aqueous titration |
|
Titration Cup Capacity |
250mL |
|
Temperature Measurement Range |
-5 to 120 degrees Celsius |
|
Temperature Measurement Accuracy |
±0.1℃ |
|
Communication Methods |
2 USB ports, 232 serial ports, Ethernet |
|
Filling Unit |
Built-in liquid filling unit |
|
Simultaneous Liquid Addition Module Unit |
(Standard configuration) Includes 2 sets of built-in titration and liquid addition channels |
|
Number of Expandable Liquid Addition Channels |
8 channels |
|
Titration Tube Specifications |
1ml, 5ml, 10ml, 25ml, 50ml (10ml is the standard size) |
|
Resolution of the Burette |
1/48,000 |
|
Time for Filling the Burette with Liquid |
10 seconds (100% liquid filling speed) |
|
Control Unit |
PC with software (computer provided separately) |
|
Automatic Sampler |
Can be used in conjunction with the GT robot injection system for the analysis of large quantities of samples |
|
Self-Check Function |
Automatically checks the instrument status upon startup |
|
Calibration Function |
Yes |
|
Apply Editing Function |
Yes |
|
Storage Space |
More than 300G |
|
Default Method Storage |
Greater than 300G (Note: Assumed to be "Default method storage space" based on context) |
|
Compliance & Management Functions |
Compliant with FDA, GMP, and GLP;Equipped with audit tracking, hierarchical management, and electronic signature |
|
Pipeline |
PTFE titration tube (corrosion-resistant) |
|
Stirring Method |
Top-mounted spiral stirrer or magnetic stirrer |
|
PTFE Valve |
Imported corrosion-resistant rotary valve |
|
Micro-Detection Electrode |
Imported |
|
Micro-Volume Infusion Pump |
Imported |
![]()
![]()
![]()
![]()
![]()