Product Details:
|
Sample Dimensions: | 300 × 300 × (10-50) Mm | Specimen Size: | 230×230 ~ 250×250 Mm |
---|---|---|---|
Power Supply: | 220V, 50Hz, ≤5 KW | Warranty: | 1 Year |
Certification: | Includes Calibration Certification | ||
Highlight: | 220v thermal stability tester,50hz thermal stability tester,220v thermal conductivity tester |
1.Description
This instrument is a thermal conductivity tester for thermal insulation materials developed from our LRS-2 water flow plate method thermal conductivity tester. Compared with LRS-2, it has improved resolution and automation, shortened test time, easier maintenance, and more reliable instrument performance. This instrument uses the protective heat flow meter method to detect the thermal conductivity of thermal insulation materials at high temperatures. It is suitable for testing the thermal conductivity of refractory insulation, ceramic fibers, felt, textiles, boards, bricks and other materials at different temperatures. It is widely used in material analysis and testing in colleges and universities, scientific research institutions, quality inspection departments and production plants.
2.Standard:
This instrument reference standard: ASTM C518-10 Test method for determining steady-state heat flux and heat transfer characteristics by heat flow meter method; ISO 8301:1991 and GB/T 10295-2008 Determination of steady-state thermal resistance and related characteristics of thermal insulation materials (heat flow meter method), etc.
3.Technical Parameter.
Specification Item | LRS-4A | LRS-3A | LRS-3B |
Thermal Conductivity Range | 0.001-3 W/m·K | 0.0010-3 W/m·K | 0.0010-3 W/m·K |
Measurement Accuracy | Better than ±5% | ±5% | ±5% |
Hot Surface Temp. Range | 200-1200°C | 100-1200°C | 100-1200°C |
Calorimetric Temp. Control Method | Semiconductor cooling | Semiconductor cooling | Semiconductor cooling |
Guard Temp. Control Method | Semiconductor cooling | Semiconductor cooling | Semiconductor cooling |
Calorimetric Plate Size | 75×75 mm | 75×75 mm | 75×75 mm |
Heat Flux Meter Size | 75×75 mm | 75×75 mm | 75×75 mm |
Specimen Temp. Points | 4 points | 4 points | 4 points |
Loading/Unloading Method | Electric loading | - | - |
Pressure Range | 0-500 N | - | - |
Thickness Range | 0-120 mm | - | - |
Thickness Correction | Real-time correction by displacement meter | - | - |
Specimen Atmosphere | Air | Air | -0.095 MPa; Atmosphere protection |
Specimen Size | 230×230 ~ 250×250 mm; Thickness 10~100 mm | 200×200 ~ 250×250 mm; Thickness 10~100 mm | 200×200 ~ 250×250 mm; Thickness 10~100 mm |
Measurement Control | Fully automated PC testing, data processing, report generation, and printout. | Fully automated PC testing, data processing, report generation, and printout. | Fully automated PC testing, data processing, report generation, and printout. |
Power Supply | 220V, 50Hz, ≤5 kW | 220V, 50Hz, ≤5 kW | 220V, 50Hz, ≤5 kW |
Standard Configuration | • LRS-4A main unit • Software suite • Test thermocouples • Rubber water hose (requires tap water connection; optional water bath upgrade available at extra cost) • PC (can be user-provided) |
• LRS-3A main unit • Software suite • Test thermocouples • Rubber water hose (requires tap water connection; optional water bath upgrade available at extra cost) • PC (can be user-provided) |
• LRS-3B main unit • Software suite • Test thermocouples • Rubber water hose (requires tap water connection; optional water bath upgrade available at extra cost) • Vacuum sealing device • Vacuum pump • PC (can be user-provided) |
Optional Features | Multi-layer testing (requires additional thermocouple per layer, extra cost). | Multi-layer testing (requires additional thermocouple per layer, extra cost). | Multi-layer testing (requires additional thermocouple per layer, extra cost). |
Contact Person: Ms. Lilianne Chen
Tel: 13751328225
Fax: 86-769-83078748