Ürün ayrıntıları:
|
Model: | Al-BP-9010 | Garanti: | 1 yıl |
---|---|---|---|
Yüksek voltajlı güç kaynağı: | 400W (50kV 8mA) | İstikrar: | ≤2% |
Doğrusallığı sayan enstrüman: | ≤1% | Örnek büyüklüğü: | 40mm x 10mm (h) |
Vurgulamak: | XRF cement testing machine,wavelength-dispersive XRF spectrometer,XRF analyzer for cement |
The wavelength dispersive X-ray fluorescence spectrometer is a high-tech product developed by our company through summarizing the experiences and lessons learned from years of research and development of this type of instrument in China, and by absorbing and referring to international advanced technologies. All technical performance indicators have reached the level of similar international products. The X-ray fluorescence spectrometer can be applied in any field that requires the analysis of elements or compound components from Na to U, such as building materials (cement, glass, ceramics), metallurgy (steel, non-ferrous metals), petroleum (trace elements such as S, Pb, etc.), chemical industry, geological mining, commodity inspection, quality inspection, and even the inspection of trace elements in the human body. It is a reliable tool for both macro and micro analysis and is also used in colleges and universities as well as research institutions.
Application
The AL-BP-9010 is highly suitable for quality process control in large, medium and small cement plants (single or double kilns). It can be used to analyze major and minor oxide components in raw materials (such as limestone, sand, bauxite, magnesite and other minerals), as well as to determine conventional elements such as CaO, SiO2, Al2O3, Fe2O3, MgO, SO3, K2O, Na2O, Cl, etc. in raw meal, clinker and cement.
● Application in the steel industry: Determine the elements of Si, Mn, P, S, Cu, A, Ni, Cr, Mo, V, Ti, W, Nb in accordance with GB/T 223.79-2007.
● Applications in other industries: determination of S and P in petroleum, glass, ceramics, non-ferrous metals, mining, geology, chemical industry, quality inspection, etc.
Software Features
1.The independently developed software is a fully Chinese software system suitable for the Windows operating system. The software is easy to operate and fully conforms to the operating habits of Chinese people, with no special requirements for operators.
2.The operation interface is intuitive, allowing multiple tasks to be executed simultaneously. It features human-machine dialogue, making it convenient to modify and set various parameters.
3.Full-spectrum detection is adopted, and real-time intelligent correction of instrument drift is carried out to maintain the best operating state.
4.The instrument adopts an advanced mathematical model algorithm to calibrate the working curve, which is simple and more in line with the characteristics of the user's production process.
5.Powerful database system is supported to achieve various matrix and background interference corrections.
6.It is equipped with an online rate value batching ratio feedback regulation calculation module for the cement industry and a cement component determination module. It can statistically measure the results of production samples, helping process engineers analyze changes in batching.
7.Powerful historical record query function, enabling real-time dynamic tracking of production process changes.
8.Powerful self-diagnostic function, real-time monitoring of instrument status, and automatic protection function.
9.It features popular DCS communication protocols, enabling convenient data sharing with DCS systems.
Technical Parameters
Types of elements analyzed |
Any ten elements from 11Na to 92U |
X-ray tube |
200W, 400W thin beryllium window end-window X-ray tube (optional) |
X-ray tube cooling |
Professional circulating refrigeration cooling, no cooling water required |
High-voltage power supply |
400W (50kV 8mA), 12h stability of tube voltage and tube current: better than 0.05% |
Constant temperature chamber temperature control accuracy |
Set value ±0.1℃ |
Detector |
Gas-flow proportional detector, closed counter tube, scintillation counter |
Data processing system |
12-channel 2048-channel independent pulse height analyzer |
Vacuum system |
Independent pump station structure, double vacuum chambers, easy to maintain, maximum vacuum degree of measuring chamber: below 7Pa |
Gas-flow system |
Adopting foreign high-precision density flow control system and high-precision gas-flow density stabilization device, with pressure stability reaching ±0.01kPa |
AC 220V power supply equipment |
2kVA AC purified regulated current |
Stability |
(24h) ≤2% |
Energy resolution of counter |
≤40% |
Instrument counting linearity |
≤1% |
Measurement time for a single sample |
(Including sample changing and vacuum pumping time) ≤(2-5)min |
Sample size |
40mm x 10mm (H) |
Analytical sample surface |
max 35mm |
Sample rotation |
30rpm |
Software |
Qualitative analysis (automatic identification and analysis functions (smoothing, background subtraction)) |
Quantitative analysis |
Various matrix corrections, standard sample analysis methods, application templates |
Maintenance functions |
Automatic diagnosis, remote diagnosis |
İlgili kişi: Ms. Kaitlyn Wang
Tel: 19376687282
Faks: 86-769-83078748