Product Details:
|
| Type: | Testing Machine | Accuracy Class: | High Accuracy |
|---|---|---|---|
| Accuracy: | / | Application: | Auto Testing |
| Customized Support: | OEM, ODM, OBM | Power: | --- |
| Protection Class: | Ip56 | Voltage: | 220 V |
| Warranty: | 1 Year | Dimensions: Including Operation Platform: | 523(D)*332(W)*290(H)mm |
| Highlight: | SPF analyzer ISO 24443 compliant,sunscreen SPF measuring device,cosmetics sun protection tester |
||
LONROY CHNSpec SPF-660 ISO 24443 Cosmetics Sun Protection Factor Analyzer ISO 23675 Sunscreen SPF Value Measuring Device
Typical Applications
1. R&D and Quality Control: In vitro rapid analysis for SPF/UVAPF, formula verification, and production batch stability monitoring.
2. Multiple test objects: Various sunscreen cosmetics and raw materials, including lotions, creams, powders, liquids, and cushion-type products.
3. Entire cosmetics industry chain: Empowering brand owners, OEM/ODM manufacturers, and sunscreen ingredient companies with R&D innovation.
4. Authoritative testing institutions: Suitable for food and drug regulatory authorities, customs technical centers, and third-party testing laboratories.
5. Academic research: Supporting universities and dermatological research institutions in photobiology and new sunscreen material research.
Core Advantages
1. Transient UV Spectrum Acquisition: Full-Band Scan in 1 Second
Advanced 500KHz high-speed spectral acquisition technology fundamentally revolutionizes the slow point-by-point scanning mechanism.Detector arrays enable nanosecond-level synchronous response, completing full-band data collection from UVA to UVB (280–500nm) within 0.1ms integration time. Parallel computing supports the entire workflow—from data capture and signal averaging to SPF result analysis—completed in just 1 second.
Outstanding SNR: Ultra-fast acquisition enables thousands of real-time averages in a very short time, easily achieving SNR > 1000:1, ensuring fast and accurate SPF evaluation.
2. Intelligent Integrated Control System with Built-In Touchscreen
Equipped with a high-performance quad-core industrial processor and an optimized embedded OS, eliminating dependence on external PCs. All operations are performed via an industrial-grade capacitive touchscreen following SOP-driven logic, reducing the learning curve and minimizing errors. From spectrum acquisition and dark current correction to SPF value and UVA/UVB transmittance calculations, a single button initiates automated sequences for seamless“sample-to-result”processing.
3. High Dynamic Range Photodetection: SPF Measurement up to 2000
Equipped with a research-grade high dynamic range photodetector array, it achieves an ultra-wide dynamic range of 50,000:1, ensuring precise capture of signals from high light transmittance to sunscreen. The quantum efficiency in the ultraviolet band is close to 90%, making signal response more sensitive. Advanced cooling technology suppresses dark noise to an ultra-low level of <0.1 mv/rms, allowing clear signal acquisition even with millisecond-level exposures. It easily handles extreme challenges with ultra-low transmittance below 0.05%, with a detection sensitivity of up to SPF 2000.
4. Ultra-Wide UV Coverage: Comprehensive UVA/UVB Evaluation
Adopting a symmetrical optical path design and research-grade back-illuminated area array detectors, it achieves an ultra-wide ultraviolet spectral measurement range from 280nm to 500nm. This not only fully covers the UVB (280–315nm) and UVA (315–400nm) bands defined by international standards, but also extends the measurement range into the UVA-I long-wave region up to 500nm, ensuring the capture of even the finest spectral details.
Exceeding Standard Requirements: It far exceeds the 400 nm upper limit specified in standards such as ISO 24443, ISO 23675, FDA 2012 & 2019, providing decisive data support for the evaluation of cutting-edge sunscreen products.
High-Resolution Analysis: With an optical resolution of 2 nm, it can accurately resolve every detail of the spectrum, enabling a more comprehensive and precise evaluation of the true broad-spectrum UV protection efficacy of cosmetic products. This ensures your test results maintain undisputed integrity and authority in all applications.
5. Global Standards Compatibility: Built-In Authoritative Testing Methods
Preloaded with multiple authoritative standards, including the Cosmetic Safety Technical Specification, ISO 23675 cosmetic sunscreen testing standard, and ISO 24443 UVA protection efficacy determination method. The system instantly locks all key parameters of the selected standard—specific wavelength range, data interval, and SPF calculation weighting—ensuring that every test complies with the requirements of the target regulations.
Structured Update Support: With a modular software architecture, when international standards are updated or new versions are released, you can quickly gain compatibility with the latest standards through a simple software upgrade package. This ensures long-term effectiveness of your investment and keeps you aligned with the international forefront at all times.
LONROY CHNSpec SPF-660 ISO 24443 Cosmetics Sun Protection Factor Analyzer ISO 23675 Sunscreen SPF Value Measuring Device
Technical Specification
|
Model |
SPF-600 |
SPF-620 |
SPF-660 |
|
Wavelength range |
280-400nm |
280-450nm |
280-500nm |
|
Wavelength accuracy |
±0.1nm |
||
|
Bandwidth (FWHM) |
<2nm |
||
|
Wavelength step (data interval) |
1nm |
||
|
Optical structure |
D/0 (integrating sphere illumination, 0° viewing angle) |
||
|
Integrating sphere material |
FPET |
||
|
Integrating sphere aperture diameter |
1.27cm |
||
|
Sample irradiation area |
1.26cm² |
||
|
Light source |
Pulsed xenon lamp |
||
|
UV dose per measurement cycle / single test UV irradiation dose |
< 0.2 J/cm² |
||
|
Sample stage |
Manual three-dimensional positioning platform |
||
|
Measurement range: transmittance |
0-100% |
||
|
Measurement range: absorbance |
0-3.3A |
||
|
Measurement range: SPF value determination |
1-1000 |
1-2000 |
|
|
Measurement range: single scan time |
~1s |
||
|
Measurement indicators |
SPF (Sun Protection Factor), UVAPF, UVA/UVB (UVR), Critical Wavelength, Spectral Transmittance, Absorbance |
SPF (Sun Protection Factor), UVAPF, UVA/UVB (UVR), Critical Wavelength, Spectral Transmittance, Absorbance, High Energy Visible Light (HEVIS) |
|
|
Supported test methods and certification standards |
Cosmetic Safety Technical Specification, |
Cosmetic Safety Technical Specification, |
|
|
Computer interface |
USB 2.0,RS-232 |
||
|
Power requirement |
12V 5A |
||
|
Operating environment / working environment |
0–50 °C, 0%–70% RH (non-condensing) |
||
|
Dimensions: including operation platform |
523(D)*332(W)*290(H)mm |
||
|
Dimensions: excluding operation platform |
325(D)*332(W)*290(H)mm |
||
|
Optional accessories |
AS01 PMMA reference plate set |
AS01 PMMA reference plate set |
|
![]()
![]()
![]()
![]()
![]()
![]()
Contact Person: Kaitlyn Wang
Tel: 19376687282
Fax: 86-769-83078748