ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine

Orzecznictwo
CHINY DONGGUAN LONROY EQUIPMENT CO LTD Certyfikaty
CHINY DONGGUAN LONROY EQUIPMENT CO LTD Certyfikaty
Im Online Czat teraz

ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine

ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine
ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine

Duży Obraz :  ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine

Szczegóły Produktu:
Miejsce pochodzenia: CHINY
Nazwa handlowa: Lonroy
Orzecznictwo: ISO ASTM CE
Zapłata:
Minimalne zamówienie: 1
Cena: Negotaible
Szczegóły pakowania: Drewniany pakiet
Czas dostawy: 5-8 dni roboczych
Zasady płatności: L/C, D/A, D/P, T/T, ZARZĄDENIE WESTOLA
Możliwość Supply: 200

ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine

Opis
Zakres kontroli temperatury: Normalna temperatura-300 ℃ Prędkość ogrzewania: (120 ± 10) ℃/h (12 ± 1) ℃/6min; (50 ± 5) ℃/h (5 ± 0,5) ℃/6min
Błąd wskazania temperatury: 0,1 ℃ Dokładność kontroli temperatury: ± 0,5 ℃
Maksymalny błąd deformacji: ± 0,001 mm Zakres pomiaru deformacji: 0-2mm
Liczba próbnych ramek: 3PCS Obciążenie ciężar pręta: 68g
Zakres przedziału badawczego: 64 lub 100 mm Medium grzewcze: Olej metylosilikonowy lub olej transformatorowy
Metoda chłodzenia: Powyżej 150 ℃: naturalne chłodzenie; Poniżej 150 ℃: chłodzenie wody lub naturalne chłodzenie Moc ogrzewania: 4KW
Klasa ochronna: IP56 Woltaż: 220 V, 380 V
Przykładowe ramki półek: 3PCS
Podkreślić:

ISO 306 Vicat heat tester

,

ASTM D648 thermoplastic testing machine

,

Vika softening temperature tester

ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine
Product Introduction

The Thermal Deformation Vicat Softening Point Temperature Tester features PLC programmable controller temperature control with computer display operation. This precision instrument offers simple operation, stable performance, and high accuracy, with real-time monitoring of test temperature and deformation amount. The system automatically stops heating at test completion and can print test reports and curves. Essential for quality inspection units, universities, and industrial enterprises.

Product Characteristics
  • Sample frame lifting function for easy positioning at test start/end
  • Designed for measuring thermal deformation temperature and Vicat softening point of non-metallic materials including plastics, rubber, nylon, and electrical insulating materials
Test Standards Compliance
  • GB/T1633 - Thermoplastic Vika softening temperature (VST) determination
  • GB/T1634 - Plastic load deformation temperature (Part 1: General test method)
  • GB/T8802 - Plastic pipe fittings softening temperature determination
  • ISO 75-2013 - Plastic load deformation temperature measurement
  • ASTM D 648 - Plastic thermal deformation temperature test method
  • ASTM D 1525 - Plastic Vicat softening test method
Standard Accessories
  • Industrial computer: 1 unit
  • Printer (HP, optional): 1 unit
  • Electric control box: 1 unit
  • Host machine: 1 unit
  • Sample shelf frames: 3 units
  • Hot deformation pressure heads: 3 units
  • Vicat needles: 3 units
  • Weight sets (including weights in boxes): 3 sets
  • Multi-purpose power socket: 1 unit
Weight Configuration (Customizable)
Weight Quantity Weight Quantity
1000g 12 932g 3
500g 3 200g 6
100g 3 50g 3
20g 6 10g 6
5g 3 2g 3
1g 3
Technical Specifications
Parameter Specification
Temperature control range Normal temp - 300℃
Heating speed (120±10)℃/h (12±1)℃/6min; (50±5)℃/h (5±0.5)℃/6min
Temperature indication error 0.1℃
Temperature control accuracy ±0.5℃
Maximum deformation indication error ±0.001mm
Deformation measurement range 0-2mm
Number of sample frames 3 units
Load rod and tray weight 68g
Test span range 64 or 100mm (standard dependent)
Heating medium Methyl silicone oil or transformer oil
Cooling method Above 150℃: natural cooling; Below 150℃: water cooling or natural cooling
Heating power 4kW
ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine 0 ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine 1 ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine 2 ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine 3 ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine 4 ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine 5 ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine 6 ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine 7 ISO 306 Vicat Heat Distortion Temperature Tester ASTM D648 Thermoplastic Vika Softening Temperature Testing Machine 8