Product Details:
|
| Type: | Oxygen Bomb Calorimeter | Accuracy Class: | Standard Accuracy |
|---|---|---|---|
| Accuracy: | ±1% | Customized Support: | OEM, ODM, OBM |
| Power: | 50, Electronic | Protection Class: | IP55 |
| Voltage: | 220 V | Warranty: | 1year |
| Highlight: | oxygen bomb calorimeter coal meter,calorific value meter with warranty,differential scanning calorimeter coal testing |
||
XRY-1A Oxygen Bomb Calorimeter Coal Calorific Value Meter
![]()
Product description
XRY-1A oxygen bomb calorimeter is based on the People's Republic of China national standard GB/T 213 "Determination of calorific value of coal", GB/T 384 "Determination of calorific value of Petroleum products", the People's Republic of China National Metrological verification regulation JJG672 "Oxygen bomb calorimeter" and Shanghai enterprise standard Q/YXYY 10 Design and manufacture according to requirements of XRY-1A type oxygen bomb calorimeter.
The heat capacity of the instrument is 14400 ~ 14500J/K, suitable for the determination of non-aqueous petroleum products (gasoline, jet fuel, diesel and fuel oil, etc.) and coal, coke, paraffin and other combustible substances calorific value measurement by calorimeter oxygen bomb.
main technical characteristics
1, the instrument adopts self-sealing oxygen bomb, all the structure is made of stainless steel, strong enough to withstand the maximum pressure generated by solid combustion (60 ~ 70 atmospheric pressure), and can withstand the greater pressure generated by liquid fuel.
2. The inner water cylinder of this instrument is made of stainless steel sheet, the section is pear row, the water cylinder is loaded with 3000 grams of water, the water cylinder is provided with an electric stirrer, to ensure that the temperature of the water bath in the inner water cylinder is uniform.
3. The outer water jacket of the instrument is a double-layer container, which is filled with water during the experiment. The water temperature inside the cylinder is uniform through the water jacket agitator, which forms a constant temperature environment to meet the requirements of the test.
main technical parameters and indicators
1, heat capacity: (14400 ~ 14500) J/K.
2, resolution: 0.001K.
3, calorific value: ±60J/g.
4, repeatability error: ≤0.2 % (Grade C).
5, oxygen bomb pressure: 20MPa.
6, temperature measurement range: (10 ~ 35)℃.
7, the use of ambient temperature: 20℃±5℃, in a measurement process temperature fluctuation is not more than 1℃.
8, storage temperature measurement data: 31.
9, relative humidity: ≤85%.
10, working power supply: AC (220±5%) V, 50Hz.
11. Power consumption of the whole machine: no more than 150W.
12, shape size: 60mm×46mm×43mm (length × width × height).
Packing list
|
serial number |
name |
Pcs |
|
1 |
Calorimeter main engine |
1 |
|
2 |
(including oxygen bomb, water jacket, water cylinder, agitator, calorimeter controller) |
1 |
|
3 |
Bullet bracket |
1 |
|
4 |
Oxygen bomb mount |
1 |
|
5 |
sensor |
1 |
|
6 |
Thermometer (0-50 ℃), 0.1 ℃ |
1 |
|
7 |
Thermometer Fixing plug (Silicone plug 2#) |
10 m |
|
8 |
Ignition wire (diameter 0.1 nickel chromium wire) |
2 |
|
9 |
crucible |
1 |
|
10 |
Air release valve |
1 |
|
11 |
Oxygen pressure reducer |
1 |
|
12 |
Oxygen catheter |
5 |
|
13 |
O type sealing ring (diameter20×2.4mm) |
5 |
|
14 |
O type sealing ring (diameter 8×1.9mm) |
5 |
|
15 |
O type sealing ring (diameter 6×1.9mm) |
2 |
|
16 |
Sealing ring (large Type O ring) |
1 |
|
17 |
Ignition connection wire |
1 |
|
18 |
Water suction apparatus |
10 |
|
19 |
Benzoic acid |
4 |
|
20 |
Thermometer Retaining Ring (1#) |
1 |
|
21 |
Instruction manual |
1 |
|
22 |
Software operating CD |
1 |
|
23 |
Product qualification certificate |
1 |
![]()
![]()
![]()
![]()
![]()
![]()
Contact Person: Kaitlyn Wang
Tel: 19376687282
Fax: 86-769-83078748