Product Details:
|
| Voltage: | 220 V | Protection Class: | Ip56 |
|---|---|---|---|
| Sampling Volume Range: | 2 - 10 Ml | Storable Experimental Methods: | 200 Items |
| Solvent Temperature Monitoring: | 12-channel | Rotational Speed Resolution: | 0.1 RPM |
| Swinging Amplitude: | ≤ 0.4 Mm | Rotating Shaft Deviation: | ≤ 1.0 Mm |
| Speed Regulation Range: | 10 - 250 RPM | Steady-State Error: | ±0.3 RPM |
| Temperature Adjustment Range: | Room Temperature To 50.0℃ | Temperature Resolution: | 0.1℃ |
| Temperature Control Error: | ±0.2℃ | Number Of Dissolution Cups: | 12 |
| Number Of Sampling Times: | 20 | ||
| Highlight: | 12-channel Solvent Temperature Monitoring Dissolution Tester,200 Storable Experimental Methods Dissolution Rate Analyzer,220 V Voltage Dissolution Testing Instrument |
||
Full Automatic Dissolution Tester Dissolution Rate Analyzer Dissolution Testing Instrument Manufacturer Price
Technical Specification
|
Instrument Model |
LR-A355 |
|
Swinging Amplitude of the Stirring Paddle |
Less than or equal to 0.4 mm (≤ 0.4 mm) |
|
Swing Amplitude of the Rotating Basket |
Less than or equal to 0.4 mm (≤ 0.4 mm) |
|
Deviation Between the Rotating Shaft and the Axis of the Dissolution Cup |
Less than or equal to 1.0 mm (≤ 1.0 mm) |
|
Speed Regulation Range |
(10 - 250) RPM (Revolutions Per Minute) |
|
Rotational Speed Resolution |
0.1 revolutions per minute (0.1 RPM) |
|
Steady-State Error |
±0.3 revolutions per minute or less (±0.3 RPM or less) |
|
Temperature Adjustment Range |
Room temperature to 50.0℃ (Note: Corrected from "Room temperature: -50.0℃" for logical consistency, assuming it refers to a range starting from room temperature up to 50.0℃) |
|
Temperature Resolution |
0.1 degrees Celsius (0.1℃) |
|
Temperature Control Error |
±0.2 ℃ or less |
|
Solvent Temperature Monitoring |
12-channel |
|
Resolution of Solvent Temperature Monitoring |
0.1 degrees Celsius (0.1℃) |
|
Number of Dissolution Cups |
Twelve (12) |
|
Automatic Center Positioning |
Yes |
|
Storable Experimental Methods |
200 items |
|
User Management |
100 users (Note: Clarified from "One hundred" to specify the count of manageable users) |
|
Sampling Volume Range |
2 - 10 ml |
|
Number of Automatic Sampling Times |
Twenty (20) |
|
Automatic Positioning of Sampling Needle |
Automatic positioning |
|
Touch Screen |
High-definition LCD touch screen |
|
Pipeline Function |
Automatic pipeline cleaning and automatic drainage functions |
|
Sampling and Fluid Replacement |
Automatic sampling and constant-temperature liquid replenishment |
![]()
![]()
![]()
![]()