Product Details:
|
Product Name: | Coulometric Karl Fischer Moisture Analyzer | Customization: | Available |
---|---|---|---|
Warranty: | 1 Year | Power Supply: | 220V 50Hz 80W |
Host Size: | 350mm * 300mm * 170mm | Temperature: | 2℃ - 50℃ |
Highlight: | Coulometric Karl Fischer moisture analyzer,Karl Fischer liquid determinator,small meter moisture analyzer |
Coulometric Karl Fischer Moisture Analyzer Coulometric Karl Fischer Liquid Determinator
Instrument Introduction
The coulometric Karl Fischer moisture analyzer adopts a 5.7-inch capacitive high-definition color touch screen. The operation interface is simple and intuitive, with a navigation-style operation method, making it easy to get started. Its unique circuit and program design features high precision, fast electrolysis speed, short equilibrium time, accurate blank subtraction, and reliable analytical results. The measurement accuracy of this instrument can reach the ppm level, making it suitable for measuring various liquid products with low moisture content.
Product Features
1. Strong environmental adaptability, with precise, accurate, and stable measurement results
The full digital intelligent control measurement during the electrolysis process, precise background current deduction, and complete elimination of the influence of environmental air humidity and stirring rate;
Exclusive use of real-time dynamic impedance method to determine the titration endpoint, resulting in more accurate measurement results;
It can set the equilibrium point (titration endpoint) to ensure the wide adaptability of the instrument to different sensitivity reagents;
2. Built-in multiple testing methods, making the testing process simpler
The carefully refined eight concentration calculation formulas cover most of the moisture measurement standards in China and abroad, and six testing methods can be selected to meet various needs;
Measurement result storage and query function: It can store 500 sets of measurement data, and comes with a built-in printer for immediate query and printing;
3. High reliability
Core components use industrial-grade data conversion chips from the United States, with excellent linearity and long-term stability;
The used components and key parts are all from international first-line brands:
IC: ANALOG, TI, ISSI, CY, SAMSUNG, Toshiba, etc. for new industrial-grade ICs
Capacitors: Murata; Inductors: TDK, Murata; Solder: Alpha; Connectors: Molex, HRS, Omron, etc.
4. Simple operation
Navigation-style menu design, functions are clear at a glance, capacitive touch screen operation, as convenient as operating a mobile phone, different from the resistive screens of other instruments, it is more convenient to use and the click is more accurate.
5. Rich display content, clear measurement process
It simultaneously displays water content, measurement time, ppm, percentage content, electrolysis current, potential, system time, etc., making the experimental process clear and enabling timely detection of problems;
6. Multiple test result units can be selected, suitable for different samples
Measurement results are automatically calculated, including percentages, ppm, mg, etc.; in line with GLP experimental records, including measurement time, moisture content, percentage, system time, etc.
Applicable National Standards
1. GB/T 606-2003 General Method for Determination of Moisture in Chemical Reagents - Karl Fischer Method
2. GB/T 8577-2010 Determination of Free Water Content in Compound Fertilizers - Karl Fischer Method
3. GB/T 11133-2015 Determination of Water Content in Petroleum Products, Lubricants and Additives - Karl Fischer Coulometric Titration Method
4. GB/T 7600-2014 Method for Determination of Moisture Content in Running Transformer Oil and Steam Turbine Oil (Coulometric Method)
5. GB/T 6283-2008 Determination of Moisture Content in Chemical Products - Karl Fischer Method (General Method)
Technical specifications
Product Model |
LR-Q432 |
Determination Principle |
Karl Fischer Coulometric Method (Electrical Method) |
Measurement Speed |
2.8 mg H₂O/min (Maximum) |
Measurement Range |
3 μg - 300 mg |
Measurement Accuracy |
3 μg (10 μg - 100 μg H₂O); ≤ 0.3% (Water content > 100 μg H₂O) (Excluding sample volume error) |
Measurement Resolution |
0.1 μg H₂O |
Relative Moisture Content Range |
1 ppm - 100% |
Electrolytic Current |
0 - 500 mA adjustable |
Moisture Concentration Resolution |
0.001 ppm |
Concentration Units |
%, ppm, mg/kg |
Stirring Speed |
Continuous touch adjustment |
Drift Value/Blank Value Deduction |
Automatically deducted |
Special Functions |
Automatic drift compensation, automatic deduction of environmental and background moisture, fault self-check indication |
Display and Operation |
Color touch screen |
Sample Number |
Users can freely set sample numbers |
Data Storage |
500 entries |
Printing Function |
Built-in low-energy high-speed thermal printer, 58mm paper width |
Printed Content |
Different contents based on user measurement formulas and measurement results |
Calendar/Time |
Current time, date, detection time and date display and printing output |
Operating Environment |
Temperature 2℃ - 50℃, humidity < 90% |
Host Size |
350mm * 300mm * 170mm |
Power Supply Voltage |
220V 50Hz 80W |
Weight |
Net weight of the host: 4kg; Weight after packaging: 8kg |
Optional Equipment |
If the product is insoluble in organic solvents (methanol), or reacts with the components of the Karl Fischer reagent (methanol, iodine, etc.), it can be used with a heating furnace |
Contact Person: Ms. Kaitlyn Wang
Tel: 19376687282
Fax: 86-769-83078748