Product Details:
|
Power Supply: | 220V / 50Hz; Power ≤ 2kW | Measurement Accuracy: | ≤ ±3% |
---|---|---|---|
Repeatability: | ≤ ±1% | Voltage Range: | 0-30V |
Warranty: | 1 Year | Certification: | Includes Calibration Certification |
Highlight: | multifunctional thermal stability tester,multifunctional thermal conductivity tester,220v thermal stability tester |
1.Description:
This instrument is a thermal conductivity tester for thermal insulation materials developed from our LRS-2 water flow plate method thermal conductivity tester. Compared with LRS-2, it has improved resolution and automation, shortened test time, easier maintenance, and more reliable instrument performance. This instrument uses the protective heat flow meter method to detect the thermal conductivity of thermal insulation materials at high temperatures. It is suitable for testing the thermal conductivity of refractory insulation, ceramic fibers, felt, textiles, boards, bricks and other materials at different temperatures. It is widely used in material analysis and testing in colleges and universities, scientific research institutions, quality inspection departments and production plants.
2.Standard
GB/10294-2008, ISO8302:1991 (Determination of steady-state thermal resistance and related properties of thermal insulating materials - Guarded hot plate method)
GB/T 3392-1982 "Test Method for Thermal Conductivity of Plastics - Guarded Heat Plate Method"
GB/T 3139 (Test method for thermal conductivity of fiber-reinforced plastics) (Test method for thermal conductivity of fiberglass reinforced plastics), etc.
3.Technical Parameter.
Thermal Conductivity Range | 0.0010~3.0000 W/(m·K), displayed with 4 decimal places |
Measurement Accuracy | ≤ ±3% |
Repeatability | ≤ ±1% |
Hot Surface Temperature | |
- Range | Room Temperature ~ 95°C |
- Resolution | 0.01°C |
Cold Surface Temperature | |
- Range (Standard) | 0 ~ 60°C |
- Resolution | 0.01°C |
- Control Method | Thermostatic Water Bath |
Optional Low-Temperature Testing | Custom ranges: -20°C~60°C, -30°C~60°C, or -40°C~60°C (additional cost applies) |
Main Power Supply | 220V / 50Hz; Power ≤ 2kW |
Calorimetric Power Supply | |
- Voltage Range & Resolution | 0-30V, Resolution: 0.0001V |
- Current Range & Resolution | 0-3A, Resolution: 0.0001A |
Automation & Reporting | Computer-connected automatic testing, data processing, report generation, and printing |
Required Sample Dimensions | |
Model | Dimensions (mm) |
LRH-III | 200 × 200 × (5-20) |
LRH-300 / LRH-ZD-300 | 300 × 300 × (10-50) |
LRH-400 / LRH-ZD-400 | 400 × 400 × (10-80) |
LRH-600 / LRH-ZD-600 | 600 × 600 × (10-100) |
Contact Person: Ms. Lilianne Chen
Tel: 13751328225
Fax: 86-769-83078748