Product Details:
|
Dimension: | 850mm*410mm*450mm | Weight: | 30Kg |
---|---|---|---|
Test Speed: | < 1min/ Time (excluding Sample Dispersion Time) | Test Range: | 0.1μm -800μm |
Highlight: | Laser Particle Size Distribution Analyzer,Particle Size Distribution Analyzer 800μm,Particle Size Distribution Analyzer 0.1μm |
Main performance characteristics
★ Advanced optical path design: LR-N5200 adopts Fourier Transform Detection (FTD) technology to ensure maximum range with the shortest focal length, effectively improving the resolution of the instrument; the unique high-density detection unit makes THE LR-N5200 capable of detecting ultra-small particles. The high density detection unit gives THE LR-N5200 a superb seamless full-range detection capability.
★ Enable new software: The third generation software is officially commercialized. The new software optimization algorithm makes the test results more accurate and stable, and the real-time stored test data will never be lost; the third generation software supports the fuzzy search function, so that all the tested samples can be easily found no matter how long they have been tested for; the human-computer interaction is more reasonable.
★ Four generation detector: 5200 particle size meter at the same time enabled the fourth generation detector, all imported German materials processing, oxidation resistance, photoelectric conversion efficiency of more than ten years almost zero attenuation.
LR-N5200 Fully Sealed Fiber Semiconductor Laser LR-N5200 adopts high stability and long life Japan Opnext Fully Sealed Fiber Semiconductor Laser, the excellent stability makes LR-N5200 has strong test repeatability, on the basis of 5100-H to do the laser power adjustable, and the maximum laser power has reached 20MW.
★ Laser intelligent management system: LP-N5200 is the first to add the laser intelligent management system, intelligent management system real-time monitoring of the working status of the instrument, once the work command is received, the intelligent management system will instantly light up the laser, high-performance laser will reach a stable working state within 3 seconds. After the sample test, the intelligent management system will automatically turn off the laser, the laser will basically not decay. Theoretically, the particle size analyzer can be used without replacing the laser (optional).
★ Automatic test: truly automatic test, what you do is just put in the sample, no interference data without manual selection of data.
★ Ultrasonic anti-dry burning function: after painstaking research and development, LR-N5200 can realize ultrasonic anti-dry burning function, to avoid damage to ultrasonic in the case of no water.
★ New SOP self-editing function: In order to meet the test needs of different samples, LR-N5200 realizes the SOP self-editing function, edit different test procedures according to different samples, edit and save once and then directly use next time.
Dustproof and shockproof design: the whole instrument is sealed to greatly improve the service life of the internal components. The unique shockproof structure can effectively avoid the interference of external vibration to the instrument, so that the test results are more stable and reliable.
★ Strong anti-corrosion design (optional) : It can be equipped with acid-resistant, alkali-resistant, oil-resistant (including all solvent oils), and organic solvent-resistant (such as phenol, n-hexane and other organic solvents) according to the actual needs of customers.
★ Optical path automatic calibration: The new self-developed auto-alignment system consists of stepper motors, precision guides, precision controllers and a software system with a minimum step size of 1 micron, which ensures that the laser beam is focused through the detector from the center point, improving the accuracy and repeatability of the test results. The auto-alignment system is standard on all types of laser particle sizers.
Unique microcirculation system: The whole dispersion circulation system has been optimized design, more than 80 ml of dispersing medium can be circulated test, truly realize the micro-circulation test; optimized design to ensure that no residue left after draining and the accuracy of the next test results. (Optional micro test)
★ Free exhaust bubble design: the new design makes the whole test will not have bubble into the test sample window, avoid bubble interference.
Dew point measurement function: The system has a dew point measurement function, and the software can provide a sample window fog reminder according to environmental changes; the instrument also has internal temperature, humidity and test medium temperature display function.
organic solvents (such as phenol, n-hexane and other organic solvents).
★ Dispersant automatic filling system: the new 5200 increased the dispersant automatic filling system, greatly improving the stability of the instrument dispersion; It not only avoids the tedious artificial addition but also greatly prolongs the cleaning cycle of the sample window (if there is no lack of dispersant calcium carbonate industry can basically not clean the sample window).
★ Channel steel guide: the new 5200 light path guide is uniformly upgraded from aluminum alloy to thickened channel steel, the light path system is more stable and reliable, and greatly reduces the influence of temperature and humidity on the light path.
★ Sample no residue design: the instrument pipeline and drainage structure are optimized design, the instrument pipeline, circulation pump no liquid residue, to avoid the impact on the next test data.
★ Sample window quick change device: newly designed sample window quick change device, make sample window more convenient and fast change.
2. Main technical parameters
specifications | LR-N5200(With high) | |
Execution standard | GB/T 19077-2016/ISO 13320:2009 | |
Test range | 0.1μm -800μm | |
Number of detector channels | 70 | |
Accuracy error | < 1% (National standard sample D50 value) | |
Repeatability error | < 0.5% (National standard sample D50 value) | |
Free bubble | With no exhaust bubble design, no bubble interference data more accurate | |
Misoperation protection | The instrument has self-protection function for misoperation and does not respond to misoperation | |
Laser parameter | Imported fiber output high power laser λ= 635nm, P> 10mW | |
The light path calibration | Automatic optical path calibration | |
Dispersion method | ultrasonic | Frequency: F =40KHz, power: P =80W, time: adjustable; With ultrasonic anti-dry burning |
Circulating and stirring | Integrated design of circulation mixing, speed: 100-3950 RPM adjustable speed | |
Circular flow | Rated flow: 0-10L/min Adjustable rated power: 25W | |
The sample pool | Self-designed boiling sample tank, better dispersion effect, capacity: 190-600ml can be normal test | |
Microinjection (optional) | The instrument can be equipped with micro automatic test device,10 ml can be cyclic test (optional) | |
Dustproof and shockproof design | The whole machine adopts dustproof and shockproof design | |
Anti-corrosion design (optional) | Can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oil), resistance to organic solvents (such as phenol, n-hexane and other organic solvents). | |
Software functions | Analysis patterns | Including free distribution, R-R distribution and log-normal distribution, classification by order statistical mode, etc., to meet the different requirements of different industries for sample size statistical methods |
Statistical methods | Volume distribution and quantity distribution, in order to meet the different statistical methods of granularity distribution in different industries | |
Statistical comparison | It can make statistical comparison and analysis for multiple test results, and can obviously compare the difference of test results of different batches of samples, samples before and after processing and different time, which has strong practical significance for the quality control of industrial raw materials | |
To DIY | User-defined data to display, according to the percentage of particle size, according to the percentage of particle size or according to | |
According to the template | The percentage of particle size interval is calculated to meet the characterization of particle size test in different industries. Diameter distance, consistency, interval accumulation, etc | |
The test report | The test report can be exported to Word, Excel, Bmp, and Text files, enabling you to view test reports and reference test results in scientific research articles on any occasion | |
Multilingual support | Chinese and English language interface support, can also be embedded in other languages according to user requirements. | |
Intelligent operation mode | Truly automatic unmanned intervention operation, no human interference, you only need to add the sample to be tested as prompted, the test results of better repeatability. | |
Operating mode | One-click automatic software operation mode | |
The test speed | < 1min/ time (excluding sample dispersion time) | |
volume | 850mm*410mm*450mm | |
The weight of the | 30Kg |
Contact Person: Lilianne Chen
Tel: 13751328225
Fax: 86-769-83078748