Product Details:
|
Size: | 460mm × 330mm × 350mm | Net Weight: | 15KG |
---|---|---|---|
Power Supply: | 220/240V, 50/60Hz | Certification: | Includes Calibration Certification |
Warranty: | 1 Year | ||
Highlight: | astm paint testing equipment,astm paint testing instruments,automatic paint testing equipment |
BGD 240 ASTM D 3278 Automatic Flash Point Tester
1.Description
Flash Point is the lowest temperature, as measured in the prescribed manner, of the test portion corrected to a barometric pressure of 101,3 kPa, at which application of an ignition source causes the vapour of the test portion to ignite momentarily and the flame to propagate across the surface of the liquid under the specified conditions of test.
BGD 240 Automatic Flash Point Tester is designed according to rapid equilibrium closed cup method. It can rapidly test flash point for paints, including water-borne paints, varnishes, binders for paints and varnishes adhesives, solvents, petroleum, and related products.
It conforms to ISO 3679,ISO 3680,ASTM D 3278,ASTM D3828 etc
Characters
* Can detect the flash point at a specific temperature between -35 ºC and 105 ºC (BGD 240/1)or RT to 300 ºC(BGD 240/2)at average rate heating.
* All functions are achieved through touch screen and digital display.
* Built in two test procedures:rapid balanced mode and average rate heating mode
* Various parameters, such as the heating mode, time, temperature and the average rate heating can be set by the user themselves.
* Planning board action, the decline of the ignition, the detection of flash point is done automatically.
* The gas ignition sources can be provided directly by the laboratory, you can also use the portable butane gas tank.
* Built-in cooling module is used to shorten the cooling time between the two tests.
* Amend barometric pressure automatically Flash Point is the lowest temperature, as measured in the prescribed manner, of the test portion corrected to a barometric pressure of 101,3 kPa, at which application of an ignition source causes the vapour of the test portion to ignite momentarily and the flame to propagate across the surface of the liquid under the specified conditions of test.
2.Technical Parameter
Flash Point Temperature Range | BGD 240/1: -35ºC to 105ºC BGD 240/2: RT (Room Temperature) to 300ºC |
Tested Flash Point Accuracy | ±0.5ºC (≤100ºC) ±2ºC (>100ºC) |
Sample Volume | BGD 240/1: 2ml BGD 240/2: 4ml |
Heating Rate | Customizable, fastest speed: 5ºC/min |
Cooling Method | BGD 240/1: Built-in cooling module (external cooling water, flow rate >1L/min) BGD 240/2: Air cooling |
Output Interface | USB |
Size | 460mm × 330mm × 350mm |
Net Weight | 15 kg |
Operating Temperature | 15ºC ~35ºC |
Power Supply | 220/240V, 50/60Hz |
Contact Person: Ms. Lilianne Chen
Tel: 13751328225
Fax: 86-769-83078748