Product Details:
|
Temperature Range: | Room Temperature ~1450ºC | Heating Rate: | 0.1~100ºC/min |
---|---|---|---|
Constant Temperature Time: | 0 ~ 300min Arbitrary Setting | Cooling Time: | 15min (1000ºC...100 ºC) |
Power Supply: | AC220V 50Hz | ||
Highlight: | TGA Thermo Gravimetric Analyzer,TG Thermo Gravimetric Analyzer,TGA Thermogravimetric Analysis Machine |
1. Furnace body heating adopts precious metal platinum rhodium wire double row winding system, reduce interference.
2. The tray sensor is made of precious metal platinum rhodium alloy, which has the advantages of corrosion resistance.
3. Power supply, the circulation cooling part is separated from the main engine to reduce the influence of heat and vibration on the microthermal balance.
4. The top opening lid structure is easy to operate. It is very difficult to put samples into the upper part of the furnace, and it is easy to damage the sample bars.
5. The host machine adopts water constant temperature device to isolate the thermal influence of the heating furnace body on the chassis and micro thermal balance.
6. Furnace body can be changed according to customer's demand.
1. Using imported 32-bit ARM processor Cortex-M3 kernel, sampling speed, fast processing speed.
2. 24-bit four-way sampling AD collects DSC signal, TG signal and temperature T signal.
3. Power supply and water circulation part, independently controlled by 8bit single chip microcomputer, so that the main engine and cooling part separate, do not interfere with each other, but they are closely connected, cooling part accept the control of the main engine.
4. USB two-way communication is adopted between the software and the instrument to fully realize remote operation. The parameter setting and operation stop of the instrument can be carried out through computer software.
5. 7-inch full-color 24bit touch screen, good man-machine interface.TG calibration can be realized on the touch screen
4. Technical parameters
Temperature range | room temperature ~1450ºC |
temperature resolution | 0.01ºC |
temperature fluctuation | ±0.1ºC |
Heating rate | 0.1~100ºC/min |
Temperature control mode | heating, constant temperature, cooling |
Cooling time | 15min (1000ºC...100 ºC) |
Balance measurement range | 0.1mg ~ 2G, can be extended to 30g |
Accuracy | 0.01mg |
Constant temperature time | 0 ~ 300min arbitrary setting |
Display mode | Large LCD display of Chinese characters |
Atmosphere device | built-in gas flowmeter, including two gas switch and flow size control (Atmosphereinert: oxidizing, reducing, static, dynamic) |
Software | The software can automatically record TG curves for data processing and print experimental reports |
Data interface | standard USB interface |
Power supply | AC220V 50Hz |
Contact Person: Lilianne Chen
Tel: 13751328225
Fax: 86-769-83078748