Product Details:
|
Temperature Range: | Room Temperature -1200ºC | Heating Rate: | 0.1~100ºC/min |
---|---|---|---|
DSC Range: | 0 ~ + 600mW | Constant Temperature Time: | 0 ~ 300min |
Power Supply: | AC220V 50Hz | ||
Highlight: | Synchronous Heat Differential Scanning Calorimeter,Differential Scanning Calorimeter 50Hz,DTA Differential Thermal Analyzer |
DSC Synchronous Plastic Thermogravimetric Analysis Differential Thermal Analyzer
1. Product introduction
Thermogravimetric analysis (TG, TGA) is the study of the thermal stability and composition of materials by observing the change in mass with temperature or time during warming, constant temperature or cooling. It is widely used in research and development, process optimization and quality control in the fields of plastics, rubbers, coatings, pharmaceuticals, catalysts, inorganic materials, metallic materials and composite materials.
Measurement and study of the following properties of materials:
Thermal stability, decomposition processes, adsorption and desorption, oxidation and reduction, quantitative analysis of composition, additives and fillers.
2. Technical parameters
Temperature range | room temperature -1200ºC |
temperature resolution | 0.01ºC |
temperature fluctuation | ±0.1ºC |
Heating rate | 0.1~100ºC/min |
Temperature control mode | PID algorithm control, heating, constant temperature, cooling |
Constant temperature time | 0 ~ 300min arbitrary setting |
Balance measurement range | 0.01mg ~ 3g, can be extended to 30g Program control, realize multi-stage heating control |
DSC range | 0 ~ + 600mW |
DSC resolution | 0.001mW |
Precision of weighing system | 0.01mg |
constant temperature time | 0 ~ 300min arbitrary setting |
Display mode | 24bit color, 7 inch LCD touch screen display |
Atmosphere device | built-in gas flowmeter, including two gas switch and flow size control, atmosphere: inert, oxidizing, reducing, static, dynamic |
Software | Intelligent software can automatically record TG curves for data processing and print experimental reports |
Curve scanning | heating scanning and cooling scanning |
Power supply | There is an isolation shield between power supply and weighing system to avoid ac interference. AC220V 50Hz |
Operating software | it can switch to meet the application switching test of differential, differential heat, thermogravimetric and synchronous heat |
Communication interface | USB communication |
The computer can draw temperature and TG and DSC curves during the test. |