Product Details:
|
Temperature Range: | -170~600ºC | DSC Range: | 0 ~ ±600mW |
---|---|---|---|
Heating Rate: | 0.1 ~ 80ºC/min | Cooling Equipment: | Liquid Nitrogen Cooling |
Data Interface: | Standard USB Interface | Power Supply: | AC220V/50Hz |
Highlight: | Precision Differential Scanning Calorimeter,Lab Differential Scanning Calorimeter |
ISO 11357 DSC Differential Scanning Calorimeter Thermal Analyzer Liquid Nitrogen Cooling
1. Product Introduction
LR-300 is the highest precision one among the DSC series products launched by our company, its sensor is E-couple with imported material, high precision, high sensitivity, good repeatability, the signal is protected by collector shielding, strong anti-interference, very high baseline stability and repeatability.
LR-300 Differential Scanning Calorimeter can be used for glass transition temperature, phase change temperature, melting point, enthalpy, curing temperature and product stability, oxidation susceptibility period and other tests. It is capable of performing research in the fields of tubing, polymer, chemical, food, medical, etc. It serves universities, enterprises, third-party measurement and quality inspection units, and has a wide range of applications to meet the testing needs of various industries.
2. Technical features
1. Industrial grade 7 inch touch screen, display rich information
2. New furnace structure, better baseline, higher precision. The heating method adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is superior to the traditional heating method.
3. USB communication interface, strong commonality, reliable and uninterrupted communication, supports self-resuming connection function.
4. Automatic switching of two air flow, fast switching speed, short stability time. At the same time, a protective gas input is added.
5. Software is simple and easy to operate.
6. Ultra-high sensitivity, accuracy, 0.001 MW, 0.001ºC
7. The technical index is exquisite, the performance is superior, the price ratio is high, and the application is wide.
3. Technical parameters
Temperature range | -170~600ºC, liquid nitrogen refrigeration |
temperature resolution | 0.01ºC |
temperature fluctuation | ±0.01ºC |
Temperature repeatability | ±0.1ºC |
Heating rate | 0.1 ~ 80ºC/min |
Constant temperature time | 0~400 |
Temperature control mode | heating, cooling, constant temperature |
DSC range | 0 ~ ±600mW |
DSC resolution | 0.001mW |
DSC sensitivity | 0.001mW |
Power supply | AC220V/50Hz or customized |
Cooling equipment | liquid nitrogen cooling |
Atmosphere control gas | nitrogen, oxygen (automatic instrument switch) |
Gas flow | 0-300ml /min |
gas pressure | 0.2mpa |
Display mode | 24bit color, 7 inch LCD touch screen display |
Data interface | standard USB interface |
Parameter standard | equipped with standard material (indium, tin), users can adjust the temperature |
Upper computer operation software, coordinate range automatically switch, no manual adjustment; Software analysis results can be dragged at will display position | |
The instrument has multiple groups of thermocouples, one group to test the sample temperature, one group to test the internal environment temperature of the instrument, and one group to test the furnace temperature |
4. Configuration list
serial number |
name of the accessories | quantity | note |
1 | Differential instrument | 1 | |
2 | The software U disk | 1 only | |
3 | Communication data line | 2 the root | USB data communication |
4 | The power cord | 1 the root | |
5 | Aluminum crucible | 200 only | |
6 | Porcelain crucible | 100 only | Used for testing corrosive samples |
7 | Furnace cover | 3 only | Multilayer insulation |
8 | Raw tape | Volume 1 | |
9 | Standard material | One copy each of the | Indium, tin, |
10 | 10 A fuse | 5 only | |
11 | Sample spoon/sample press/tweezers | Each one | |
12 | Dust cleaning ball | 1 | |
13 | Air pipe (including joint) | 2 the root | Φ8mm |
14 | Instruction book, warranty card, certificate of quality | One copy each of the | |
15 | Fully automatic liquid nitrogen tank | 1 set of |
Contact Person: Lilianne Chen